EXPLANATION OF COMPONENTS
Operations on "Configurations" menu screen
On "Configurations" menu screen, you can perform the follow-
ing operations with function switches "F3" and "F4".
Function switch "F3"
Returns the screen to "Working Record" menu screen.
Function switch "F4"
Displays the setting screen for the selected item.
SET OPERATION RECORD DISPLAY
On "Operation Record Display" screen, the display of operation record can be set 1 Day display or Split Time
display.
1.
Press the function switch "F4" on "Configurations" menu
screen.
2.
"Operation Record Display" screen is displayed.
On "Operation Record Display" screen, you can change
the following settings.
"1 Day"
Displays the average fuel consumption from 0:00 a.m. of
the day to 0:00 a.m. of the next day.
"Split Time"
Displays the average fuel consumption during the Split
Time measurement period.
Select "Split Time" to start the automatic measurement of
fuel consumption.
On "Operation Record Display" screen, you can perform the following operations with function switches "F1" to
"F4".
Function switch "F1"
Moves to the next item (1 line below).
When it is on the last line, it moves to the first line.
Function switch "F2"
Moves to the previous item (1 line above).
When it is on the first line, it moves to the last line.
Function switch "F3"
Cancels the selected change and returns the screen to "Configurations" menu screen.
Function switch "F4"
Allocates the selected change, and returns the screen to "Configurations" menu screen.