Barrier Speed
Soft stop speed
Aux Relay Setup.
Blue-bus Setup.
Power Settings.
Controller setup.
IEC Standards
Reset and Restore
Advance programming options and their definitions.
This option allows you to reduce the maximum run speed in either both open and close direction or
independently.
This option allows you to adjust the speed the barrier slows down to when the soft stop switches are
triggered.
Lock mode - This option allows you to control either a electro-mechanical lock like an electric rim lock or a
magnetic lock. The relay on time can be adjusted in strike lock mode.
RX1 Module - This option allows you to combine the third channel of the receiver with the auxiliary relay
to operate like an ET RX1 receiver. The relay can be set to latch mode or the on relay on time can be
adjusted to any time between 1 and 60 seconds. The receiver is a single shot receiver.
Light switch - This option is used as a switch in the driveway lighting circuit where the lights will come on
as the barrier opens and will switch off after the barrier has closed again. In this mode the third channel
of the receiver when triggered will switch the auxiliary relay no matter the barrier position. There are two
on times which are adjustable. Light on time whenever barrier opens and light on time when remotely
triggered.
Traffic light - This option allows for timed traffic light switching between green and red.
This control unit can be used with the NICE Blue-bus two wire devices like the Blue-bus safety beam
products. This function must be run when adding or removing any Blue-bus devices to the system.
Battery charger - This option allows you to disable the battery charger where a larger capacity intelligent
charger has been installed additionally to maintain the battery level of additional batteries larger than
7Ah. By disabling the built in charger you remove any possibility of interfering with the external charger's
diagnostics thus optimising the external battery and charger's performance.
AC monitoring - This option allows you to disable the Vac mains failure monitoring on sites where a solar
panel system has been installed to maintain the battery.
LCD Contrast Adj - This allows you to adjust the contrast between the text and the background of the LCD
display.
Adv Beam Setup - In the case of a safety beam circuit being installed without an end of line resistor,
it is still possible to meet the stringent CE safety standards by activating this function that intelligently
monitors the safety beam circuit.
Alarm output setup - The Drive and Wide series of operators, monitor for tampering conditions namely;
safety beam tampering, barrier lifted in all of the series and barrier kept open for too long in the case of
the Drive 500, 600, 1000 and Wide.
Jammed open - Use this feature to adjust the length of time the barrier is permitted to remain open for
before the alarm activates.
On board alarm - Use this feature to enable or disable the on board buzzer sounding whenever the
alarm activates.
Alarm output invert - Use this feature to set the alarm output to switch to 0V (Disable) or switch from
0V (Enable) in an alarm condition.
BT on-board - Use this feature to enable or disable the on-board BT button.
Wired BT Enable - Use this feature to enable or disable the hardwired BT input.
Wired E-Stop Enable - Use this feature to enable or disable the hardwired pedestrian input.
Wired Open only Enable - Use this feature to enable or disable the hardwired loop input.
PIN Code lock-out - Use this feature to prevent any access to the programming menus.
Cycle count - Use this to see how many times the barrier has been operated. This counter cannot be reset
in the field.
Event log - Use this to see a log of the most recent barrier open and close operations.
Fault log - Use this to see a log of the last 30 fault conditions.
Trigger log - Use this to see a log of the last 30 triggers.
Last overload info - Use this to see the recorded position of the last barrier overload.
Firmware version - Use this to see the control card firmware version.
Hardware version - Use this to see the control card hardware version.
Use this feature to enable or disable IEC safety standards mode.
Set restore point - Use this to set a restore point.
Restore settings - Use this feature to restore all controller settings to the last saved restore point.
Clear logs - Use this feature to clear the event, fault and trigger logs. NB! this does not clear the cycle
counter.
Factory reset - Use this feature to default all controller settings to factory settings. NB! this does not
factory reset the receiver memory or clear the cycle counter.