Page 1
X-BAR Automatic barrier EN - Instructions and warnings for installation and use IT - Istruzioni ed avvertenze per l’installazione e l’uso FR - Instructions et avertissements pour l’installation et l’utilisation ES - Instrucciones y advertencias para la instalación y el uso DE - Installierungs-und Gebrauchsanleitungen und Hinweise PL - Instrukcje i ostrzeżenia do instalacji i użytkowania...
Incorrect installation could cause serious physi- Contents cal injury . We recommend that you read this entire manual with care before starting any work . If in doubt, do not install the product and contact the Nice technical assistance department . • CAUTION! – Important instructions: keep this manual in a safe place PICTURES .
• Mechanical strength and stability of the product: combination with the articles listed in the product catalogue of Nice S .p .a . The product is designed and constructed to ensure that, during normal use, all These requirements may not be guaranteed if the product is used in con- forces applied, impact and normal wear will not damage or impair mechanical figurations or with other products that have not been foreseen; the use of...
10 % the solar power system “Solemyo” (see paragraph 4 .9 .3) . V3 and V4 speed X-Bar runs on electric energy and in the event of a power failure the pole can Speed V5 20 % be released and moved manually . Alternatively the buffer battery model PS124 can be used (optional accessory - see paragraph 4 .9 .2), which guarantees a...
TABLE 3 - Technical specifications of electrical cables (Fig. 1) Connection Cable type Maximum admissible length A: Mains POWER SUPPLY cable cable 3 x 1,5 mm 30 m (note 1) B: Cable for BlueBus devices cable 2 x 0,5 mm 30 m C: POLE LIGHTS D: KEY-OPERATED SELECTOR SWITCH cable 30 m (note 2) cables 4 x 0,25 mm E: Built-in FLASHING LIGHT OPTIONAL FLASHING LIGHT: cable 2 x 0,5 mm 30 m FLASHING LIGHT with aerial cable RG58 shielded cable type 20 m (less than 5 m recommended) IMPORTANT – To make the connection, programming of the FLASH output must be modified (see paragraph 6.2 - Table 7) Note 1 – If the power cable is longer than 30 m, a cable with a larger cross-section is required (3 x 2.5 mm...
IMPORTANT! – NEVER CONNECT DEVICES OTHER THAN THOSE SPE- 01. Loosen the screws of the cover (Fig. 29); CIFIED. 02. Route the electric cables inside X-Bar, starting from the base towards the control unit and routing them to the left; 4.2 - Initial start-up and electrical connections 03. Connect the wires of the electric power cable to the 3-contact terminal with fuse and secure the cable with the collar (Fig.
4.9.2 - Buffer battery mod. PS124 (accessory) To insert the radio receiver, disconnect the control unit from the power mains In the event of a mains power failure, X-Bar can also be powered by a buffer and insert the receiver as shown in fig. 34 .
Compile the form “Maintenance schedule” containing all maintenance instructions for all devices in the automation and forward it to the owner . In the case of X-Bar, this form is present at the end of this manual, in the removable section .
“Bluebus” output (connected devices) and all the LEDs apart from the Bluebus LED which will flash more slowly. When the control unit receives a command normal operation is restored. When using X-Bar with the Solemyo system, a longer Stand By mode must be set . This operation is performed using the Oview programmer .
Need help?
Do you have a question about the X-bar and is the answer not in the manual?
Questions and answers