Runtime Setup - Nice WIDE M Installer's Instructions

High traffic, battery back-up traffic barrier
Table of Contents

Advertisement

Runtime Setup

From Standby status
Action
To enter the program
menu. Press and hold the
 button until buzzer
beeps.
Scroll < or > to select the
runtime setup option.
Press and release the 
button to select runtime
setup.
Scroll < or > to select the
matching model.
Press and release the 
button with the correct
model on the display.
Scroll < or > to select
the matching boom pole
length.
Press and release the 
button with the correct
length range on the
display.
Press and release < or > to
confirm either left or right
hand closing installation.
(Page 9)
When the closed position
is reached
Once warning tone has
stopped.
When the open position is
reached.
When the closed position
is reached once again.
Scroll left or right to next
program option.
Setting up the profile and runtime. (Mandatory)
Before continuing with the runtime setup ensure the soft stop switch-
- Standard mode -
es are activating momentarily before the physical end stop is reached.
- Standby
This can be done in manual mode. Re-engage the gearbox with the
boom pole at 45 o
Description
Programming menu
Display and buzzer
<or> for options
confirms.
Runtime setup
Display scrolls
<Limits NOT set>
through options.
Set Boom Type
Display asks you to
select the barrier
< Wide M >
model.
Set BoomType
Display scrolls
< Wide L >
through options.
Type Setting
Display confirms the
Wide L saved
selection is saved.
Display asks you to
Set Boom Length
select the required
< 1-2M >
boom pole length.
Length Setting
Display confirms the
setting is saved.
Saved
The boom closes
Finding Closed
slowly.Display and
Stopper
buzzer confirms.
The boom stops.
WARNING!
Display and buzzer
warn the profiling is
Profiling.
about to begin.
The boom begins
Opening.
running open at
full speed.Display
Profiling.
confirms.
The boom stops and
Closing.
begins closing again
at full speed. Display
Profiling.
confirms.
The boom stops.
Runtime setup.
Display and buzzer
<Limits set>
confirms.
EXIT back to standby
OR
status
16
Response
Display
Buzzer
x2
x1
x1
x1
x1
x1
x1
x1
Barrier
"Selected" mode
- Standby