As a motorised operator vibrates when in use, it is strongly recommended that only multiple strand flexible cables be used.
Before closing the unit, always remember to double check that all connections are securely made, that there are no stray strands flaring out that can
short circuit against other adjacent connections or bared wires and that no cables will be pulled loose when the cover is replaced on the unit.
Double check the battery connections as loose connections can cause arcing and corrosion of the battery terminals.
Terminating the AC voltage:
The ACDC power supply requires 220Vac at the operator. This 220Vac must be circuited through a weatherproof all pole isolator switch. This isolator
switch must be installed within 1,5m of the unit, must not be installed within the workings of the system and must be positioned so that it cannot
be tampered with for the outside of the property. This circuit must be certified by way of a C.O.C. (certificate of compliance) issued by a registered
electrician.
The following shows the wiring of the 220Vac and how to access the 2A fast blow 20mm x 5mm fuse located within the power supply module.
Connecting the 220Vac supply:
O
Ensure the 220Vac has been isolated.
Electrical and electronic installation and setup.
On
Terminate the 220Vac and earth as shown here.
220Vac live.
Earth.
220Vac neutral.
13
O
On
Switch the 220Vac back on.