Nortel Meridian 1 Option 11C Manual page 53

1.5 mb dti/pri
Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Extreme care must be taken when enabling the D-channel message
monitoring option due to the possible heavy volume of messages
during normal traffic. Use this command only during very light or no
traffic conditions for trouble-shooting purposes. Remember to disable
the monitoring tool when you are finished — it does not time out.
Monitor enabled status is saved by EDD and will remain enabled even
after a SYSLOAD.
The port (TTY) performing the monitoring must have MTC and BUG
programmed.
Table 11
DTI/PRI commands (LD 60)
Command
DISI C
DISL C
ENLL C
LCNT (C)
RCNT (C)
SLFT (C)
STAT (C)
RLBK
DTI/PRI Maintenance
WARNING
Action
Disable DTI/PRI card when idle
Force disable DTI/PRI card
Enable DTI/PRI card
List alarm counters
Reset alarm counters
Do DTI/PRI self-test
List DTI/PRI status
Remote loopback
Option 11C
Page 53 of 100
1.5 Mb DTI/PRI