PRI Implementation
553-3011-310
Standard 13.00
3
From an overhead viewpoint, with the daughterboard parallel above the
NTAK09 and the connector pins aligned over the connector sockets, line
up the mounting holes on the daughterboard (Figure 4) with the tops of
the standoffs on the NTAK09.
4
Slowly lower the daughterboard towards the NTAK09, keeping the
standoffs in line with all four holes, until the holes are resting on the tops
of the four standoffs.
If more than a very slight amount of pressure is required at this point, the
connector pins may not be aligned with the connector socket. If so, lift
the daughterboard off the NTAK09 and return to step 2.
5
Gently apply pressure along the edge of the board where the connector is
located until the standoffs at the two corners adjacent to the connector
snap into a locked position. Then press down on the two corners on the
opposite side until they also are locked into place.
January 2002