Nortel Meridian 1 Option 11C Manual page 29

1.5 mb dti/pri
Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

LD 17 – Add a D-channel Interface.
Prompt
Response
REQ
CHG
TYPE
ADAN
- ADAN
NEW DCH xx
CHG DCH xx
OUT DCH xx
- CTYP
DCHI
MSDL
TMDI
- CDNO
1-50
- PORT
1
- DES
<CR>
- USR
PRI
- IFC
xx
- - DCHL
xx
- OTBF
1-(16)-127
PRI Implementation
Description
Change existing data.
Action Device And Number.
Add a primary D-channel (any unused SDI port.)
Change a primary D-channel.
Out the primary D-channel, where:
xx =0-79.
DCHI = D-channel configuration for the NTAK09 card or
NTAK93.
MSDL = the NTBK51 Downloadable D-channel
daughterboard.
TMDI = D-channel configuration on TMDI (NTRB21)
card.
Card slot number to be used as the primary
DDCH/DCHI.
Card slots 10, 20, 30, 40, and 50 are only applicable for
D-channel configuration of ISL or VNS.
PORT must be set to 1.
Designator.
D-channel is for ISDN PRI only.
Interface type.
PRI card number which will be carrying the D-channel.
Must match the entry made for the "CDNO" associated
with the "DCHI" prompt above, where:
xx = 1-9 for main cabinet, 11-19 for IP expansion
cabinet 1, 21-29 for IP expansion cabinet 2, 31-39 for IP
expansion cabinet 3, and 41-49 for IP expansion
cabinet 4.
Number of output request buffers. Note: for a single PRI
link, leave this prompt at default (16). Add 5 output
request buffers per additional link.
Page 29 of 100
Option 11C
1.5 Mb DTI/PRI

Advertisement

Table of Contents
loading

Table of Contents