Table 15
D-channel monitoring commands (Part 2 of 2)
Command
ENL TMDI x MSGO
ENL TMDI x DBG
DIS TMDI x DBG
PSWD TMDI
STAT TMDI x MON
D-channel status and error conditions are reported as DCH messages. These
messages can be found in the X11 System Messages Guide (553-3001-411).
Table 16
Clock Controller commands (LD 60)
Command
DIS CC N
ENL CC N
SSCK N
TRCK XXXX N

NTAK09 DTI/PRI power on self-test

When power is applied to the NTAK09 DTI/PRI circuit card, the card
performs a self test. The LEDs directly associated with the NTAK09 circuit
card are DIS, ACT, RED, YEL, and LBK. The clock controller LED is also
included in the power on self test (see below).
DTI/PRI Maintenance
Action
Enable monitoring of outgoing D-channel
messages on link TMDI card x.
Enable debugging on TMDI card x.
Disable debugging on TMDI card x.
Print passwords.
Print monitoring commands for TMDI card x.
Action
Disable clock controller N
Enable clock controller N
Status of clock controller N
Set clock controller tracking.
Where xxxx =
PCK, Track primary clock reference source
SCLK, Track secondary clock reference
source
FRUN, Free run mode
Option 11C