Alcatel-Lucent 1850 Installation And System Turn-Up Manual page 148

Transport service switch (tss-5) | release 5.1
Hide thumbs Also See for 1850:
Table of Contents

Advertisement

Stand-alone installation testing
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
10
If Optical PTMs are inserted in the VLNC35 loop the transmitter to the receiver on one
port. wait 10 seconds and disconnect the fiber.
........................................................................................................................................................................................................................
11
The Fault LED will start flashing on the VLNC35 circuit pack.
........................................................................................................................................................................................................................
12
Verify that there is an inc. FE-LAN LOS alarm associated with the ethernet port where the
signal was removed. Use the Alarm List button on the CIT system view.
........................................................................................................................................................................................................................
13
Select Configuration -> Update System... -> Update All.
Result:
........................................................................................................................................................................................................................
14
Repeat Steps 10 to 13 for the other optical port.
........................................................................................................................................................................................................................
15
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
VLNC40/VLNC42 standalone test
This procedure will verify that the 20 10/100-Mbs ports are working on the VLIU
panel when the Alcatel-Lucent 1850 TSS-5 shelf is equipped with a VLNC40 or
VLNC42 circuit pack.This test case will use a PC set up temporarily with a specific
static IP address to verify each 100-Mb port can ping the Alcatel-Lucent 1850 TSS-5
shelf's switch IP address. This switch IP address will be removed upon completion of
these tests.
Note:
VLNC40 circuit pack as described in the "Install NE Software on a new Alcatel-
Lucent 1850 TSS-5 network Element" chapter of the Alcatel-Lucent 1850 Transport
Service Switch (TSS-5) Software Release Description.
........................................................................................................................................................................................................................
1
Connect an RS-232 cable to the RS-232 port on the VLIU labeled M2.
............................................................................................................................................................................................................................................................
6 - 2 2
The flashing fault LED on the VLNC35 will clear.
S
F
T E P S
The VLIU is installed and software has been successfully downloaded to the
Table II-1, "Part II installation checklist" (p.
Local equipment and cross-connect tests
Issue 1 November 2008
II-1).
365-372-403R5.1