Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
3)
Ʋ Single chamber housing
Spring-loaded terminals
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
Ʋ Single chamber housing
Connection cable
Ʋ Wire cross-section
Ʋ Wire resistance
Ʋ Tensile strength
Ʋ Standard length
Ʋ Max. length
Ʋ Min. bending radius
Ʋ Diameter approx.
Ʋ Colour - standard PE
Ʋ Colour - standard PUR
Ʋ Colour - Ex-version
Adjustment elements
Mode switch
Ʋ Min.
Ʋ Max.
Voltage supply
Operating voltage
Electrical protective measures
Protection rating
Housing material
Plastic
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.
3)
VEGAWAVE 62 • Two-wire 8/16 mA
– 1 x cable gland M20 x 1.5 (cable: ø 5 ... 9 mm), 1 x
blind plug M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
– 1 x plug (depending on the version), 1 x blind stopper
M20 x 1.5
for wire cross-section up to 1.5 mm² (AWG 16)
– 1 x IP 68 cable gland M20 x 1.5; 1 x blind plug
M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
> 0.5 mm² (AWG 20)
< 0.036 Ω/m (0.011 Ω/ft)
< 1200 N (270 lbf)
5 m (16.4 ft)
1000 m (3280 ft)
25 mm (0.984 in) with 25 °C (77 °F)
8 mm (0.315 in)
Black
Blue
Blue
Min. detection or dry run protection
Max. detection or overflow protection
10 ... 36 V DC (via the signal conditioning instrument)
A suitable cable is required for maintaining the protec-
tion rating.
Protection acc. to IEC 60529
IP 66/IP 67
9 Supplement
Protection acc. to NEMA
Type 4X