Optional Coupling - Danfoss DDC20 Service Manual

Axial piston pumps
Hide thumbs Also See for DDC20:
Table of Contents

Advertisement

Service Manual
DDC20 Axial Piston Pumps
Minor Repair

Optional Coupling

26 |
©
Danfoss | August 2017
Bypass valve plug
Item
Wrench size
M100
17 mm
Removal
Remove the coupling (J538).
Inspection
Inspect the coupling. If the coupling is damaged, replace it.
Reassembly
Lubricate and install the coupling.
Remove coupling
J538
Coupling
P108 580E
Torque
12 N•m [9 lbf•ft]
L1120413 | AX00000135en-US0302