1.
Identification
2.
System design
3.
Building up the pump unit
4.
Initial start up
5.
Operation
6.
Service
1. Identification
1. Bezeichnung
1. Identification
1. Identificatie
2. System design
Systems can be either:
2.1 Water hydraulic systems, in which the water is recirculated back to
tank.
2.2 Open-ended systems with water supply from a tank.
2.3 Open-ended systems with direct water-supply.
The design of the system must ensure that selfemtying of the pump
during standstill is avoided.
The inlet pressure of the pump must never exceed the outlet pres-
sure. This may typically occur in boosted or open-ended systems
with supply direct from the tap and where a bypass valve is activat-
ed. In order to avoid this, it is recommended to install a prestressed
check valve between pump and bypass valve. The opening pressure
of the check valve must be bigger or equal to the inlet pressure.
2.1 Closed water hydraulic systems, water recirculated
(The numbers 1- 3 refer to the drawing below ).
In order to eliminate the risk of cavitation, always ensure a positive
inlet pressure by observing the following guidelines:
1)
Place the tank above pump and pump inlet.
2)
Place the main filter in the return line and not in the suction line.
3)
Dimension the inlet line with a minimum pressure loss (large
flow area, minimum length of pipe, minimum number of bends/
connections, fittings with small pressure losses).
521B0838
L enntech
L enntech
info@lenntech.com Tel. +31-152-610-900
info@lenntech.com Tel. +31-152-610-900
www.lenntech.com Fax. +31-152-616-289
www.lenntech.com Fax. +31-152-616-289
Inhalt
1.
Bezeichnung
2.
Systemaufbau
3.
Aufbau der Pumpeneinheit
4.
Erste Inbetriebnahme
5.
Betrieb
6.
Wartung
DKCFN.PI.010.A4.5B
type PAH 25/32 and 50/63/70/80/100
Contenu
1. Identification
2. Conception du système
3. Montage de la pompe
4. Mise en service initiale
5. Fonctionnement
6. Service
2. Systemaufbau
Mögliche Systeme sind:
2.1 Wasserhydrauliksysteme in denen das Wasser in den Tank zurückge-
leitet und wieder verwendet wird.
2.
Offene Systeme ohne Rückführung mit Versorgung aus einem Tank.
2.3 Offene Systeme ohne ohne Rückführung, mit direkter Wasserversor-
gung.
Der Systemaufbau muß sichern, daß sich die Pumpe im Stillstand
nicht entleert.
Der Druck am Pumpeneinlaß darf den Druck am Pumpenauslaß
nicht übersteigen. Dies mag typisch in "boosted" oder offenen Sy-
stemen auftreten, die mit Leitungswasser direkt versorgt werden
und in denen ein Bypassventil aktiviert wird. Um dies zu vermeiden,
empfehlen wir die Montage eines vorgespannten Rückschlagventils
zwischen Pumpe und Bypassventil. Der Öff-nungsdruck des Rück-
schlagventils muß den Einlaßdruck übersteigen oder diesem gleich
sein.
2.1 Wasserhydrauliksysteme, Wasser rezirkuliert
(Die Nummern 1- 3 beziehen sich auf die unten abgebildete
Zeichnung ). Um das Risiko der Kavitation zu verhindern, immer sichern,
daß ein positiver Eingangsdruck vorhanden ist.Befolgen Sie folgende
Richtlinien:
1)
Den Tank über Pumpe und Pumpeneinlaß anbringen.
2)
Das Hauptfilter möglichst in der Rücklaufleitung und nicht in der
Saugleitung einbauen.
3)
Die Saugleitung mit einen minimalen Druckverlust dimensionieren
(großer Durchströmungsbereich, minimale Rohrlänge, minimale An-
zahl von Winkelverschraubungen, und Verschraubungen mit klei-
nem Druckverlust).
INSTRUCTIONS
Inhoud
1. Identificatie
2. Systeemontwerp
3. Pompmontage
4. Opstartprocedure
5. Werking
6. Onderhoud
10-2010
Pump

Advertisement

loading

Summary of Contents for Danfoss PAH Series

  • Page 1 L enntech L enntech INSTRUCTIONS info@lenntech.com Tel. +31-152-610-900 info@lenntech.com Tel. +31-152-610-900 Pump www.lenntech.com Fax. +31-152-616-289 www.lenntech.com Fax. +31-152-616-289 type PAH 25/32 and 50/63/70/80/100 Contents Inhalt Inhoud Contenu Identification Bezeichnung 1. Identificatie 1. Identification System design Systemaufbau 2. Systeemontwerp 2. Conception du système Building up the pump unit Aufbau der Pumpeneinheit 3.
  • Page 2 2. Conception du système 2. Systeemontwerp Différentes possibilités: Systeemvarianten: Systèmes hydrauliques où l’eau retourne au réservoir (l’eau “Gesloten” waterhydraulische systemen, waarbij het wa- est recirculée). ter gerecirculeerd wordt via een waterreservoir/-tank. 2. 2 Systèmes ouverts (l’eau s’échappe dans l’atmosphère) avec “Open eind”...
  • Page 3 Re 2.2 Open-ended systems, water supply from tank 2.2 Offene Systeme mit Wassertank (The numbers 1- 3 refer to the drawing below) (Die Nummern 1- 3 beziehen sich auf die unten abgebildete Zeichnung) In order to eliminate the risk of cavitation, observe the following Um das Risiko der Kavitation zu vermeiden, befolgen Sie folgende Richt- guidelines: linien:...
  • Page 4 Re 2.3 Open-ended systems with direct water supply 2.3 Offene Systeme mit direkter Wasserversorgung The pump is supplied with water direct from the water Die Pumpe wird direkt vom Trinkwassernetz oder von einer Zwischen- supply or from a booster pump. The water pressure must pumpe versorgt.
  • Page 5 -Les pertes de charge au travers du filtre seront contrôlées. lute filter zijn volgens ß10 >5000. -Pour plus de détails, contactez le réseau de vente Danfoss. -De drukval over de filter dient steeds gecontroleerd te worden. -Voor meer details over filtratie, contacteer de Danfoss verkoop- organisatie.
  • Page 6 Beachten Sie bitte, daß die empfohlene Längentoleranz eingehalten wird, da eine Axialkraft auf die Pumpewelle vermieden werden muß. Si vous désirez un montage alternatif, veuillez contacter le réseau de vente Danfoss. Respectez les tolérances appropriées afin d‘assurer un montage aisé et sans outils de l‘accouplement élastique.
  • Page 7 3.2 Direction of rotation / Drehrichtung / Sens de rotation / Draairichting pompas Is indicated by means of an arrow at the inlet side of the pump. Wird durch einen Pfeil seitlich der Einlaßseite der Pumpe angezeigt. Est indiqué par une flèche côté aspiration de la pompe. Is met een pijl bij de inlaatpoort van de pomp aangegeven.
  • Page 8 3.5 Connections / Anschlüsse / Connexions / Aansluitingen P : Pressure P : Druck T : Tank T : Tank C : Bleeding C : Entlüftung Parallel key PAH 25/32: 8 × 7 × 32 DIN 6885 Paßfeder key PAH 25/32: 8 × 7 × 32 DIN 6885 Parallel key PAH 50/63/70/80/100: 10 ×...
  • Page 9 Umgebungstemperatur: Min. 0° bis max. 50°C. Storage temperature: Min. -40°C to max. +70°C. La gertem pera tur: Min. -40° bis max. +70°C. In case of lower operating tempera tures, please contact the Danfoss Sales Bei niedrigeren Betriebstemperaturen wenden Sie sich bitte an die Dan- Organization.
  • Page 10 Gefrierpunkt absinkt, sollte die Pumpe mit einem monopropylene glycol to prevent internal corrosion or frost in the pump. Frostschutzmittel Typ Monopropylen Glycol durchgespült werden um For further information on anti-freeze media, please contact the Danfoss Korrosion oder Frostschäden im Inneren der Pumpe zu verhindern. Sales Organization.
  • Page 11 Pour plus d’information, contactez le réseau de vente ne roestvorming en vriesschade aan de pomp vermijden. Voor meer in- Danfoss. formatie betreffende antivriesmiddelen kan u steeds terecht bij de lokale Danfoss verkooporganisatie. Procédure recommandée: Aanbevolen procedure: 5.6.1 Systèmes hydrauliques avec recirculation de l’eau.
  • Page 12 Danfoss Sales Organisation. 6. Service 6. Service Danfoss Pumpen der Baureihe PAH sind speziell für lange Laufzeiten und De Danfoss PAH pompen zijn ontworpen voor een langdurige en on- geringe Wartungskosten konzipiert worden. derhoudsarme werking, met een lage levenscycluskost als gevolg.