Plug Size And Torque Chart - With Implement Pump - Danfoss DDC20 Service Manual

Axial piston pumps
Hide thumbs Also See for DDC20:
Table of Contents

Advertisement

Service Manual
DDC20 Axial Piston Pumps
Torque charts

Plug Size and Torque Chart - with Implement Pump

Item
Plug
J140/J150
HPRV
M3/E
Charge gauge/Implement return
L1/L2/L3
Case drain
M200
Bypass valve
J320
CPRV
MA/MB
System Pressure Gauge Ports
D
Implement discharge
30 |
©
Danfoss | August 2017
M3 / E
J140
M200
MA
MB
W
Warning
Do not over torque the case drain plugs (L1, L2, L3).
Port dimensions
3/4-16 UNF
9/16-18 UNF
3/4-16 UNF
9/16-18 UNF
1/2-20 UNF
9/16-18 UNF
9/16-18UNF
L1
DDC20 with Implement Pump
L3
Wrench size
24 mm
1/4 inch internal hex
5/16 inch internal hex
17 mm
17 mm
11/16 inch
1/4 inch internal hex
M3 / E
J320
L2
J150
Torque
78 N•m [57 lbf•ft]
35 N•m [26 lbf•ft]
29 N•m [21 lbf•ft]
12 N•m [9 lbf•ft]
24 N•m [18 lbf•ft]
35 N•m [26 lbf•ft]
35 N•m [26 lbf•ft]
L1120413 | AX00000135en-US0302
D
P108804