The AGV-HP(O) series scan head is designed to be dust resistant except at the beam entrance and beam
exit apertures. The scan head does not require any maintenance other than periodic cleaning. Included in this
chapter are recommended cleaning solvents.
N O T E : The scan head must be kept free of foreign matter and moisture; otherwise, the performance
and life expectancy of the scan head will be reduced.

4.1. Service and Inspection Schedule

D A N G E R : To minimize the possibility of bodily injury or death, disconnect all electrical
power prior to performing any maintenance or making adjustments to the equipment.
Inspect the AGV-HP(O) at least once per month. A longer or shorter inspection interval may be required
depending on the application and conditions, such as the duty cycle, speed, and environment.
Monthly inspections should include but not be limited to:
Visually inspect the stage and cables.
l
Re-tighten loose connectors.
l
Replace or repair damaged cables.
l
Clean the AGV-HP(O) and any components and cables as needed.
l
Repair any damage before operating the AGV-HP(O).
l
Inspect and perform an operational check on all safeguards and protective devices.
l
In general, repair and/or replacement of damaged or malfunctioning components by Aerotech field service
personnel is not possible. Repair typically requires that the unit be returned to the factory. Please contact
Aerotech Global Technical Support for more information.