Chapter 4: Maintenance; Service And Inspection Schedule; Cleaning And Lubrication - Aerotech AGV-HP Series Hardware Manual

Hide thumbs Also See for AGV-HP Series:
Table of Contents

Advertisement

AGV-HP(O) Hardware Manual

Chapter 4: Maintenance

DANGER: To decrease the risk of electrical shock, injury, death, and damage to the
equipment, obey the precautions that follow.
All service and maintenance must be done by approved personnel.
l
Before you do maintenance to the equipment, disconnect the electrical power.
l
Before you connect wires to this product, disconnect the electrical power.
l
Restrict access to the galvo when it is connected to a power source.
l
WARNING: Keep the scan head free of foreign matter and moisture to prevent a
reduction in its performance and life expectancy.
The AGV-HP(O) series scan head is designed to be dust resistant except at the beam entrance and
beam exit apertures. The scan head does not require any maintenance other than periodic cleaning.
Included in this chapter are recommended cleaning solvents.

4.1. Service and Inspection Schedule

Until you can find the correct inspection interval for your system, set the interval for once a month.
Use the system application(s) and conditions (duty cycle, speed, and environment) to define the
inspection interval.
Monthly inspections should include but not be limited to:
Visually inspect the galvo, components, and cables.
l
Re-tighten loose connectors.
l
Replace or repair damaged cables.
l
Clean the AGV-HP(O) and any components and cables as needed.
l
Repair any damage before you operate the AGV-HP(O).
l
Inspect and perform an operational check on all safeguards and protective devices.
l
It is usually not possible for Aerotech field service personnel to do repairs and/or replace
components. Contact Aerotech Global Technical Support for more information and to determine if
the AGV-HP(O) should be sent back to the factory for maintenance.

4.2. Cleaning and Lubrication

There are no elements on the AGV-HP(O) that require lubrication.
Before you use a cleaning solvent on any part of the AGV-HP(O), blow away small particles and dust
with nitrogen or, less preferably, clean, dry, compressed air.
Use isopropyl alcohol on a lint-free cloth to clean any external metal surface of the AGV-HP(O).