For your safety
6
2.6 Manufacturer declaration
In conformity with DIN EN 60079-14/2004, para. 5.2.3, point
c1, VEGASWING 51 is suitable for use in zone 2.
The operator must use the instrument as it was intended to be
used and follow the specifications of the following documents:
this operating instructions manual
l
this manufacturer declaration (24625)
l
the applicable installation regulations
l
Max. increase of the surface temperature during operation:
82 K (individual components in the instrument)
With an ambient temperature of 70 °C (158 °F) on the housing
and a process temperature of 70 °C (158 °F), the max. ambient
temperature during operation is 135 °C (275 °F).
Measures to maintain explosion protection during operation:
Operate the instrument in the range of the specified
l
electrical limit values. Permissible supply voltage: see
"Technical data"
Mount and operate the instrument in such a way that
l
ignition danger by electrostatic charge is not expected.
Make sure that no explosive atmosphere exists when the
l
plug of the connection cable is pulled or plugged
Make sure that the cable gland is tight and strain-relieved.
l
The outer diameter of the connection cable must be
adapted to the cable gland. Tighten the pressure screw of
the cable gland carefully.
The surface temperature of the housing must not exceed
l
the ignition temperature of the surrounding explosive
atmosphere
This instrument was assessed by a person who fulfils the DIN
EN 60079-14 requirements.
2.7 Environmental instructions
Protection of the environment is one of our most important
duties. That is why we have introduced an environment
management system with the goal of continuously improving
company environmental protection. The environment man-
agement system is certified according to DIN EN ISO 14001.
Please help us fulfil this obligation by observing the environ-
mental instructions in this manual:
Chapter "Storage and transport"
l
VEGASWING 51 - - contactless electronic switch