Vega VEGASWING 51 Operating Instructions Manual

Vega VEGASWING 51 Operating Instructions Manual

Vibrating level switch for liquids

Advertisement

Operating Instructions

Vibrating level switch for liquids
VEGASWING 51
- transistor (PNP)
With extended status indication
Document ID: 40552

Advertisement

Table of Contents
loading

Summary of Contents for Vega VEGASWING 51

  • Page 1: Operating Instructions

    Operating Instructions Vibrating level switch for liquids VEGASWING 51 - transistor (PNP) With extended status indication Document ID: 40552...
  • Page 2: Table Of Contents

    Function chart ........................ 17 7 Maintenance and fault rectification Maintenance ........................18 Rectify faults ........................18 Instrument repair ......................19 Dismounting Dismounting steps......................20 Disposal ......................... 20 Supplement Technical data ........................ 21 Dimensions ........................24 Editing status: 2013-03-21 VEGASWING 51 • - transistor (PNP)
  • Page 3: About This Document

    → Action This arrow indicates a single action. Sequence Numbers set in front indicate successive steps in a procedure. Battery disposal This symbol indicates special information about the disposal of bat- teries and accumulators. VEGASWING 51 • - transistor (PNP)
  • Page 4: For Your Safety

    During work on and with the device the required personal protective equipment must always be worn. Appropriate use The VEGASWING 51 is a sensor for level detection. You can find detailed information on the application range in chapter "Product description". Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions.
  • Page 5: Ce Conformity

    That is why we have introduced an environment management system with the goal of continuously improving company environmental pro- tection. The environment management system is certified according to DIN EN ISO 14001. Please help us fulfill this obligation by observing the environmental instructions in this manual: • Chapter "Packaging, transport and storage" • Chapter "Disposal" VEGASWING 51 • - transistor (PNP)
  • Page 6: Product Description

    "VEGA Tools" and "serial number search". In addition to the type label outside, you can also find the serial num- ber on the inside of the instrument. Principle of operation Application area VEGASWING 51 is a point level sensor with tuning fork for level detection. VEGASWING 51 • - transistor (PNP)
  • Page 7: Operation

    Typical applications are overfill and dry run protection. With a tuning fork of only 38 mm length, VEGASWING 51 can be also mounted e.g. in pipelines from DN 25. The small tuning fork allows use in vessels, tanks and pipes. Thanks to its simple and robust measuring system, VEGASWING 51 is virtually unaffected by the chemical and physical properties of the liquid.
  • Page 8 Protected against solar radiation • Avoiding mechanical shock and vibration • Storage and transport Storage and transport temperature see chapter "Supplement - temperature Technical data - Ambient conditions" • Relative humidity 20 … 85 % VEGASWING 51 • - transistor (PNP)
  • Page 9: Mounting

    You can find the specifications in chapter "Technical data" and on the nameplate. Switching point In general, VEGASWING 51 can be installed in any position. The instrument only has to be mounted in such a way that the tuning fork is at the height of the desired switching point.
  • Page 10 Use the recommended cables (see chapter "Connecting to power supply") and tighten the cable gland. You can give your VEGASWING 51 additional protection against moisture penetration by leading the connection cable downward in front of the cable entry. Rain and condensation water can thus drain off. This applies mainly to outdoor mounting as well as installation in...
  • Page 11: Instructions For Installation

    The position of the tuning fork is indicated by a marking on the hexagon of VEGASWING 51. With this, you can check the position of the tuning fork when screwing it in. When the hexagon touches the seal, the thread can still be turned by approx.
  • Page 12: Connecting To Power Supply

    Wiring plan Housing overview Fig. 6: Overview of the connection versions M12 x 1 plug connection Valve plug ISO 4400 Valve plug ISO 4400 with IDC method of termination VEGASWING 51 • - transistor (PNP)
  • Page 13 For this plug version you can use standard cable with round wire cross-section. The inner conductors do not have to be stripped. The plug connects the conductors automatically when screwing in. Cable diameter 5.5 … 8 mm, protection IP 67. VEGASWING 51 • - transistor (PNP)
  • Page 14 Terminal insert Plug housing Transistor output For connection to binary inputs of a PLC. Max. Min. Fig. 9: Wiring plan, Transistor output with valve plug ISO 4400 PA Potential equalisation Load resistance (contactor, relay, etc.) VEGASWING 51 • - transistor (PNP)
  • Page 15 5 Connecting to power supply Min. Max. Fig. 10: Wiring plan (housing), transistor output with M12 x 1 plug connection Brown White Blue Black Load resistance (contactor, relay, etc.) VEGASWING 51 • - transistor (PNP)
  • Page 16: Setup

    You can check the change on the signal lamp. Please note that all connected device are activated during the simulation. If VEGASWING 51 does not switch over after several tests with the test magnet, you have to check the plug connection and the con- nection cable and try it again.
  • Page 17: Function Chart

    Switching sta- Control lamp Control lamp Control lamp Yellow - cov- Green - voltage Red - fault sig- erage indication Mode max. closed Mode max. open Mode min. closed Mode min. open Failure open VEGASWING 51 • - transistor (PNP)
  • Page 18: Maintenance And Fault Rectification

    24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is available to you 7 days a week round-the-clock. Since we offer this service world-wide, the support is only available in the English language.
  • Page 19: Instrument Repair

    Attach the completed form and, if need be, also a safety data sheet outside on the packaging • Please ask the agency serving you for the address of your return shipment. You can find the respective contact data on our website www.vega.com under: "Company - VEGA worldwide" VEGASWING 51 • - transistor (PNP)
  • Page 20: Dismounting

    WEEE directive. Correct disposal avoids negative effects on humans and the environ- ment and ensures recycling of useful raw materials. Materials: see chapter "Technical data" If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. VEGASWING 51 • - transistor (PNP)
  • Page 21: Supplement

    -40 … +80 °C (-40 … +176 °F) Process conditions Process pressure -1 … 64 bar/-100 … 6400 kPa (-14.5 … 928 psig) Process temperature - Standard -40 … +100 °C (-40 … +212 °F) VEGASWING 51 • - transistor (PNP)
  • Page 22 6 m/s (with a viscosity of 10000 mPa s) Density 0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³) Operation Plug connections Specification see "Connecting to power supply" Signal lamps (LED) Ʋ Green Voltage supply on Ʋ Yellow Vibrating element covered Ʋ Red Failure VEGASWING 51 • - transistor (PNP)
  • Page 23 For that reason the associated approval documents of these instruments have to be carefully noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools" and "serial number search" as well as via "Downloads" and "Approvals".
  • Page 24: Dimensions

    " NPT ø 17 mm (0.67") Fig. 32: VEGASWING 51, standard version - thread G½ A, ½ NPT Thread G½ A (DIN ISO 228/1), ½ NPT (M12 x 1) Thread G½ A (DIN ISO 228/1), ½ NPT (valve plug ISO 4400) Thread G½...
  • Page 25 ø21,3mm ") Fig. 33: VEGASWING 51, standard version - thread G¾ A, G1 A / ¾ NPT, 1 NPT Thread G¾ A, G1 A (DIN ISO 228/1), ¾ NPT or 1 NPT (M12 x 1) Thread G¾ A, G1 A (DIN ISO 228/1), ¾ NPT or 1 NPT (valve plug ISO 4400) Thread G¾...
  • Page 26 ø21,3mm ") Fig. 34: VEGASWING 51, high temperature version Thread G¾ A, G1 A (DIN ISO 228/1), ¾ NPT or 1 NPT (M12 x 1) Thread G¾ A, G1 A (DIN ISO 228/1), ¾ NPT or 1 NPT (valve plug ISO 4400) Thread G¾...
  • Page 27 9 Supplement VEGASWING 51, hygienic versions Fig. 35: VEGASWING 51, hygienic versions Clamp (valve plug ISO 4400) Bolting (valve plug ISO 4400) SMS 1145 (valve plug ISO 4400) Switching point Length with Tri-Clamp: 53 mm (2.1 in) Length with bolting: 53 mm (2.1 in) Length with SMS 1145: 53 mm (2.1 in)
  • Page 28 Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellec- tuelle. Pour plus d'informations, on pourra se référer au site www.vega.com. VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad indus- trial. Para mayor información revise la pagina web www.vega.com.
  • Page 29 Notes VEGASWING 51 • - transistor (PNP)
  • Page 30 Notes VEGASWING 51 • - transistor (PNP)
  • Page 31 Notes VEGASWING 51 • - transistor (PNP)
  • Page 32 Subject to change without prior notice © VEGA Grieshaber KG, Schiltach/Germany 2013 VEGA Grieshaber KG Phone +49 7836 50-0 Am Hohenstein 113...