Function Chart - Vega VEGASWING 51 Operating Instructions Manual

Contactless electronic switch
Table of Contents

Advertisement

Setup
22
Caution:
It is absolutely necessary that you remove the test magnet
after the test from the instrument housing.

6.3 Function chart

The following chart provides an overview of the switching
conditions depending on the adjusted mode and level.
Level
Mode max.
Mode max.
Mode min.
Mode min.
Failure
VEGASWING 51 - - contactless electronic switch
Switching status
Switch closed
Switch open
Switch closed
Switch open
any
Switch open
Control lamp
Green
red
Green
red
flashes red