Webasto ThermoConnect TCon2 Operating And Installation Instructions page 6

Table of Contents

Advertisement

– Velcro stickers (2x)
EN
– Operating- and Installation instructions
10.2
Connections
12
7
6
1
Fig. 3
Black - Switch output 1, (0.5 A, level
same as supply voltage when con-
trolled)
Brown - ground
not in use
Blue - pushbutton with integrated
temperature sensor
Grey - Switch input 1 (+0 V...+32 V,
min. impedance 10 kΩ, high level
> 5 V, low level < 0.5 V)
not in use
Red - Supply voltage (+9 V...+32 V)
6
Brown - Pushbutton, ground
Green - Pushbutton, LED illumina-
tion
Grey - Pushbutton, switch contact
4
Yellow - W-bus
3
not in use
10.3
Installation position
NOTE
Do not install the device in the grey
2
area as shown in Fig. 4.
WHE000018A
NOTE
The vehicles with special glazing, such
as windscreen heating or sun protec-
tion glazing, can influence the recep-
tion of the ThermoConnect TCon2. For
vehicles with this type of equipment, it
is recommended to install the Thermo-
Connect TCon2 on the side of the in-
strument panel.
1
Fig. 4
10.4
Installing the unit
u
Select an installation place for the Ther-
moConnect TCon2:
– Install the ThermoConnect TCon2 only
on flat surfaces to avoid bending of the
casing.
WHE000029A
9040092A