Fb Terminal Descriptions; Terminals; Control Terminals Block Designations - Watt Drive V2500 Series Manual

Table of Contents

Advertisement

Section 3

FB Terminal Descriptions

3.1) Terminals

Terminal Symbols
Power source of FB (FSW1 can be switched to 12V or 5V)
VP
Output Voltage: (+12VDC ±5% 200mA) or (+5VDC ±2% 400mA)
Power source (VP) and input signal (A, B) common
DCM
Input signal from Pulse Generator. Input type is selected by TSW2.
A, A, B, B
Please See section 3.4.
FB output signal for use with RPM Meter. (Open Collector)
A/O, B/O
Maximum DC24V 100mA
FB output signal (A/O, B/O) common.
COM
3.2) Wiring Notes
The control, power supply and motor leads must be laid separately. They must not be
fed through the same cable conduit / trunking.
1.
Please use a shield cable to prevent interference. Do not run control wire parallel to
any high voltage AC power line (220 V and up).
2.
Connect shielded wire to DCM only.
3.
Recommended wire size 0.21 to 0.81mm
4.
Wire length:
Types of Pulse
Generators
Output Voltage
Open Collector
Line Driver
Complementary
3.3)

Control Terminals Block Designations.

Maximum Wire Length
50m
50m
300m
70m
Fj1
Connect to V2500
series control board
Wiring Terminals
TSW1 TSW2
FB-02
Select the power
source and output
of Pulse Generator
Descriptions
Maximum 500KP/Sec
2
(AWG24 to AWG18).
Wire Gauge
2
1.25mm
(AWG16) or above
A/O
B/O
COM
VP
DCM
OC
12V
HTL
A
A
B
5V
TP
TTL
B
B-7
B

Advertisement

Table of Contents
loading

Table of Contents