APPENDIX A: TECHNICAL SPECIFICATIONS
Voltage Class
OPTI-line V2500-0_ _ _ _yW1
Max. Applicable Motor Output (kW)
Max. Applicable Motor Output (HP)
Rated Output Capacity (kVA)
Rated Output Current (A)
Recommended
WATT motor *)
Maximum Output Voltage (V)
Rated Input Current (A)
Rated Voltage
Frequency Tolerance
Control System
Output Frequency Resolution
Torque Characteristics
Overload Endurance
Accel/Decel Time
V/F Pattern
Stall Prevention Level
Frequency Setting
Operation Setting
Signal
Multi-Function Input Signal
Multi-Function Output Indication
Analog Output Signal
Other Functions
Options
Protection
Cooling Methods
Installation Location
Pollution Degree
Ambient Temperature**)
Storage/ Transportation Temp.
Ambient Humidity
Vibration
Dimensions (mm)
V2500-0wxyz_W1
Weight
EMC-conformity
cable len.(2nd env.)
cable len.(1st env.)
*) 4-pole motor - for details on motor type and data please refer to the current motor catalogue EUSAS'03
**) Max. Ambient Temp. is 50°C for size E (5.5kW to 11kW) and G (30kW to 45kW) inverters
055T
075T
5.5
7.5
7.5
10
9.9
13.7
13
18
50 Hz
134S4 134M4 161M4 161L4
87/100Hz
114M4 134S4 134M4 134ML4 161M4 161L4 180M4 180L4 200L4 226S4
101LA4
14
19
SPWM (Sinusoidal Pulse Width Modulation, carrier frequency 1-15kHz)
0.1 to 3600 seconds (4 Independent settings for Accel/Decel Time)
Keypad
Potentiometer-5KΩ/0.5W, DC 0 to +10V or -10 to +10V (Input impedance 47KΩ),
External
Signal
Keypad
External
Digital Inputs DI1 to DI6 can be combined to offer various modes of operation,
Signal
Multi-step selection 0 to 15, Jog, accel/decel inhibit, first to forth accel/decel switches, counter,
AC Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Indication, Local/Remote
AVR, S-Curve, Over-Voltage, Over-Current Stall Prevention, Fault Records, Adjustable Carrier
Frequency, DC Braking, Braking Chopper (up to 11kW), Momentary Power Loss restart, Auto
Tuning, Frequency Limits, Parameter Lock/Reset, new Sensorless Vector Control, Counter,
PID Control, Fan & Pump Control, PLC, MODBUS Communication, Reverse Inhibition
Filter, Braking Resistor/Chopper, internal PG-Feedback for closed loop Vector Control,
Communication Modules for DeviceNet and ProfiBus DP (coming soon).
Self-testing, Over Voltage, Over Current, Under Voltage, Overload, Overheating,
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
o
-10
C to 40
9.80665m/s
W
200
200
H
323
323
D
183.2 183.2 183.2 205.4
size
E
E
kg
8
10
optional external EMC-filter according to EN61800-3 amendment A11
m
60
80
m
15
15
400/460V class (ff)
110T
150T
185T
11
15
18.5
15
20
25
18.3
24.4
28.9
24
32
38
180M4
Proportional to Input Voltage
25
32
39
3-phase 342...528 Vac
47 – 63 Hz
Including auto-torque boost & auto-slip compensation;
starting torque up to 150% at 1.0Hz
150% of rated current for 1 minute
Adjustable V/F pattern (for different types load)
20 to 250%, Setting of Rated Current
Setting by ! "
RS-485 interface, 4 to 20mA (Input impedance 250Ω),
Multi-Function Inputs 1 to 6 (16 steps, Jog, up/down)
Set by RUN, STOP and JOG
RS-485 serial interface (MODBUS).
PLC operation, external Base Block (NC, NO), etc.
indication, PLC Operation indication and Auxiliary Motor Output
Analog frequency/current signal output.
External Fault, Electronic thermal, Ground Fault.
Fan-cooled
o
o
o
C (-10
C to 50
C without blind plate) Non-Condensing and not frozen
-20
Below 90% RH (non-condensing)
2
(1G) less than 20Hz, 5.88m/s
200
250
250
323
403.8
403.8
205.4
E
F
F
13
13
13
80
75
50
15
20
15
A-2
220T
300T
370T
450T
22
30
37
30
40
50
34.3
45.7
55.6
45
60
73
180L4 200L4 226S4 226M4 251M4 281S4
49
60
63
0.01Hz
2
o
o
C to 60
C
2
(0.6G) at 20 to 50Hz
250
370
370
403.8
589
589
205.4
260
260
F
G
G
13
36
36
45
50
50
15
20
20
550T
750T
45
55
75
60
75
100
69.3
84
114
91
110
150
90
130
160
370
425
425
589
660
660
260
264
264
G
H
H
36
50
50
25
25
25
15
15
15