Wiring diagrams

N L1
1
2
S1 S2
S3
<5°
BAT
Tf
Tf
LED
~
- +
1
2
S1 S2
S3
<5°
BAT
Tf
Tf
LED
~
- +
N L1
1
2
S1 S2
S3
<5°
BAT
Tf
LED
Tf
S4
S5
S6
<80°
S4
S5
S6
<80°
S4
S5
S6
<80°
AC 230V / 5A
This limit switch is possible to connect in following two versions:
IP 67
a)
-25°C ... +120°C
b)
32
if the arm is moving ... connect wire 1+2
if the arm is moving ... connect wire 1+4
1(COM) - black wire
2(NC) -
gray wire
4(NO) -
blue wire