HBM C16i Series Mounting Instructions page 19

Hide thumbs Also See for C16i Series:
Table of Contents

Advertisement

Available languages

Available languages

C16i
CAUTION
Before loading the bridge for the first time by driving on it
with a truck / vehicle, do in any case adjust the lateral
stops such that the load cells' permissible skewings or
lateral displacements of the load introduction parts are
not exceeded (see chapter 8 "Dimensions"). Otherwise,
the load cells or load introduction parts might be dam­
aged.
CAUTION
Adjust lateral stops of
the weighing platform
Notice
Type C16i... load cell is metal‐clad by laser‐welding and
made from rustproof materials. Therefore they comply
with protection class IP68 according to EN 60 529
(IEC 529) under the stated test conditions (see chapter 7
"Specifications").
In general, the load cell permit steam jet cleaning. How­
ever, the conditions for max. pressure, temperature, etc.,
stated in the EN 60 529 for protection class IP69K, must
be observed.
A1461-2.0 HBM: public