Available languages

Type
Max. capactity (E
Nominal temperature range (B
Service temperature range (B
Storage temperature range (B
Limit load (E
)
L
Breaking load (E
Permissible dynamic load
(F
)(vibration amplitude according
srel
to DIN 50100)
Deflection at E
max
Weight (G) with cable, approx.
Protection class according to
EN60529 (IEC529)
Material:
Meas. body + housing
Cable fitting
Sealing
Cable‐sheath
1)
The data for Non-Linearity (d
(TK
) are typical values. The sum of these data meets the requirements for p
C
OIML R60.
2)
Please refer to the power supply table in the Installation instructions!
C16i
)
max
)
T
)
tu
)
tl
)
d
(s
), approx.
nom
), Hysteresis error (d
lin
A1461-2.0 HBM: public
20 t
-10 ... +40 [14...104]
°C [°F]
-20 ... +70 [‐4...158]
-50 ... +85 [‐58...185]
% of
E
max
mm
0.65
kg
2.2
IP68 (test conditions 100 h
at 1 m water column)
IP69 K (water at high pressure,
steam jet cleaning)
thermoplastical elastomer
) and Temperature effect on sensitivity
hy

Specifications

C16i D1
30 t
40 t
150
> 350
70
0.75
0.85
2.4
3.0
stainless steel
stainless steel
R
Viton
= 0.8 according to
LC
60 t
1.22
3.8
25