OPERATOR CHECKLIST
If your machine is water-cooled, check the water
lines for kinks or leaks. Kinks can occur when the
machine is moved back and forth for cleaning or
maintenance. Deteriorated or cracked water lines
should be replaced only by a Taylor mechanic.
Your machine is equipped with an auxiliary
refrigeration system. Check the auxiliary
condenser for accumulation of dirt and lint. Dirty
condensers will reduce the refrigeration capacity
of the mix cabinet. Condensers must be cleaned
monthly with a soft brush.
Important! Never use screwdrivers or other metal
probes to clean between the fins.
®
The Horizon
Pump
7
Note:
Replace the Horizon
months.
7-2
Figure 7-1
®
pump tubing every three
Models 8752 and 8756 with Horizon® Pump
Winter Storage
If the place of business closes during the winter months,
it is important to protect the freezer by following certain
precautions, particularly if the building is subject to
freezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water-cooled freezers, disconnect the water supply.
Relieve pressure on the spring in the water valve. Use air
pressure on the outlet side to blow out any water
remaining in the condenser.
Important! Failure to follow this procedure may cause
severe and costly damage to the refrigeration system.
Your local Taylor distributor can perform this winter
storage service for you.
15187
Wrap detachable parts of the freezer (such as the beater,
blades, driveshaft, and freezer door) and place these
parts in a protected, dry place. Rubber trim parts and
gaskets can be protected by wrapping them with
moisture-proof paper. All parts should be thoroughly
cleaned of dried mix or lubrication, which can attract mice
and other vermin.
Operator Checklist