Download Print this page

Wayne Submersible Automatic Utility Pump WEU250 Operating Instructions page 2

Submersible automatic utility pump
Hide thumbs Also See for Submersible Automatic Utility Pump WEU250:

Advertisement

Operating Instructions
General Safety
Installation
Information
(Continued)
IMPORTANT: This pump is not designed
for use in septic tanks or underground
To reduce the risk of electric shock,
vaults to handle raw sewage or effluents.
the motor must be securely and
It should never be used in hazardous or
adequately grounded. This can be
explosive locations. Do not use power
accomplished by inserting plug
cord to lift motor. Always use the handle.
directly into a properly installed
and grounded 3-prong, grounding-
NOTE: Pump is supplied with a discharge
type receptacle (as shown in Figure
check valve and a garden hose adapter.
1).
The check valve should be used to
prevent water from back flushing
Where a 2-prong wall receptacle is
through the pump when it shuts off.
encountered, it must be replaced
with a properly grounded 3-prong
1. Pump should be located and should rest
receptacle installed in accordance
on a level solid foundation. A minimum
with the NEC and local codes and
of one and a half (1-1/2) inches of water
ordinances.
is recommended to properly prime
12. All wiring should be performed by a
utility pump. Do not suspend pump by
qualified electrician.
means of the discharge pipe or power
13. It is strongly recommended that this
cord. Keep pump inlet screen clear. Do
unit is plugged into a Ground Fault
not install pump directly on clay, earth
Circuit Interrupter (GFCI). Consult a
or sand surfaces. Protect pump from
local electrician for installation and
extreme heat and cold. Use pipe joint
sealant to ensure airtight pipe connec-
availability (See Figure 1).
tions
The pump motor is
equipped with an
2. Thread discharge (outlet) pipe into
automatic resetting thermal protector
pump carefully to avoid stripping or
and may restart unexpectedly.
cross threading.
Protector tripping is an indication of
motor overloading as a result of
3. To install garden hose, install the
operating the pump at low head (low
adapter provided with the pump.
discharge restriction), excessively high
Thread garden hose onto the check
or low voltage, inadequate wiring,
valve fitting.
incorrect motor conditions, or a
defective motor or pump.
NOTE: The garden hose must be 3/4 inch
or larger to keep friction as low as
14. Protect electrical cord from sharp
objects, hot surfaces, oil, and
possible.
chemicals. Avoid kinking the cord.
A 1 inch sump discharge hose adapter
Replace or repair damaged or worn
can be connected directly to the pump
cords immediately.Use wire of ade-
body using Teflon
quate size to minimize voltage drop
4. Run discharge pipe/hose away from
at the motor.
the pump.
15. Do not handle a pump or pump
5. It is strongly recommended that this
motor with wet hands or when
pump motor be electrically connected
standing on a wet or damp surface,
to a ground fault interrupter. Consult
or in water.
your local electrician for availability
If your basement or
and installation.
room has water or
Power Supply: Pump is designed for 120
moisture on the floor, do not walk on wet
volt, 60 Hz operation and requires a
area until all power has been turned off. If
circuit of 15 amperes or more capacity.
the shut-off box is in basement, call the
electric company to shut-off service to the
Pump is supplied with a 3-wire cord set
house, or call your local fire department
with grounding-type plug for use in a 3-
for instruction. Failure to follow this
wire, grounded outlet.
warning can result in fatal electrical shock.
prong. Cutting cord or plug will void
warranty and may make pump inoperable
6. Do not bend, kink or cut power cord.
Protect cord from sharp objects, hot
surfaces, oil and chemicals. Replace
damaged cord.
7. After all piping and controls have
been installed, unit is ready for
operation.
www.waynepumps.com
Operation
Do not
touch
pump, pump motor, water or
discharge piping when the
pump is connected to electrical
power. Do not handle a pump or pump
motor with wet hands or when standing
on wet or damp surface, or in water.
Never touch the pump or discharge
piping when unit is operating or fails to
operate. Always disconnect the pump
cord (power) before handling.
Risk of
electrical shock! This pump is
supplied with a grounding
conductor and grounding type
attachment plug. Use a grounded
receptacle to reduce the risk of fatal
electrical shock.
This pump is designed for 120 Volt, 60
Hz operation and requires a 15 amp
circuit or more and is equipped with a
3-wire cord set with a grounding-type
plug for use in a 3-wire grounded
outlet. For safety, this pump should
always be electrically grounded to a
suitable electrical ground. NEVER cut
off the round grounding plug.
1. Plug unit into 120 volt outlet. Pump
will run for 30 seconds.
TIME-SEQUENCED AUTOMATIC
OPERATION WHEN SUBMERGED IN A
MINIMUM OF 1-1/2 INCHES OF
WATER.
If no water is detected, pump
shuts off for 120 seconds. Then
pump will run for 5 seconds. If no
water is detected, pump will shut off
®
tape.
for another 120 seconds.
The 5 / 120 cycle will repeat as long
as no water is detected.
If water is introduced during the
120 seconds and you do not
want to wait, simply unplug the
pump and plug back in. This will
restart the 5 / 120 cycle.
2.The pump will pump water below
1/4 inch, but will not remove all of
the water. Use a mop or squeegee to
remove the remaining water.
Make certain that
the pump is
Do not cut off the
unplugged before attempting to service
round grounding
or remove any component. This pump is
assembled in the factory using special
equipment; therefore only authorized
service dealers or qualified electricians
should attempt to repair this unit.
Improper repair can cause an electrical
shock hazard.
2
Funcionamiento
Conector de
(Continuación)
Manguera
de jardín
Si el protector de sobrecarga para la
bomba repetidamente, desconecte la
Válvula de
bomba del suministro de energía y
Control
revise para encontrar el problema. El
bajo voltaje, los cables de extensión,
el impulsor atascado, el exceso de
Válvula de
Cebado
retropresión en la manguera de
Automático
descarga (como cuando bombea por
15 m (50 foot) de manguera
enrollada), o si la bomba trabaja
demasiado tiempo sin carga, todo eso
puede causar el recalentamiento.
El agua que pasa por la bomba enfría
Figura 2
el motor, permitiendo que la bomba
trabaje sin parar con cualquier
AIRE EN LA BOMBA
profundidad de agua superior a
Cuando una bomba aspira aire, sigue
6,4 mm (1/4 inch). Sin embargo, si la
sobrecarga del motor para la bomba,
trabajando pero el agua no circula. El
deje que se enfríe por una hora antes
aire en la bomba causa el
de volver a arrancar. El motor no
recalentamiento y daño. Esta bomba
vuelve a arrancar antes de que el calor
tiene una válvula de cebado
automático en la parte superior del
de la sobrecarga se haya disipado.
cuerpo de la bomba. Si usted sospecha
que la bomba tiene aire, desconecte la
bomba, limpie el orificio alrededor de
la válvula de cebado automático con
un sujetador de papeles o con un
pedacito de alambre, y vuelva a
arrancar la bomba.
Guía de Diagnóstico de Averías
Problema
Causas Posibles
La bomba no se enciende o
1. La bomba está en "Modo de Descanso"
no funciona
2. Hay un fusible quemado o el cortacircuito se
desactivó
3. El voltaje es muy bajo
4. El motor está dañado
5. El impulsor (la bomba está llena de desperdicios)
6. No cebada en forma adecuada
La bomba se apaga y
1. La bomba recorre su ciclo automáticamente
enciende
independientemente
2. El agua está muy caliente
3. La bomba ha estado funcionando sin bombear
agua. El nivel de agua es muy bajo
La bomba hace ruido o vibra
1. Los cojinetes están desgastados
excesivamente
2. Escombros en la cavidad del impulsor
3. Las conexiones de las tuberías al edificio son muy
rigidas o están muy flojas
La bomba funciona pero
1. El voltaje de la línea es muy bajo
practicamente no bombea
agua.
2. Hay de spertidicos en el impulsor en en el desagüe
3. Alguna pieza está dañada o desgastada
4. La bomba no es la adecuada para la a plicación
5. Compruebe si la válvula se pegó cerrada
6. Hay aire en la voluta (parte espiral)
Si el problema persiste, retire la
válvula de retención y conecte el
conector de la manguera de jardín
directamente a la bomba.
Si la salida de la manguera/ tubo de
descarga está sumergida, debe haber
3,2 mm (1/8 inch) en la manguera/ tubo
de descarga para impedir que entre
aire en la bomba. Este orificio debe
estar abierto al aire.
Mantenimiento
1.Esta bomba no necesita lubricación.
2.Si desmantela el motor antes del
vencimiento de la garantía, la misma
se anulará. Igualmente esto podría
crear fugas y daños. Si necesita
reparaciones, enviela a donde la
compró o a un electricista. En caso de
que tenga que desmantelar el motor
deberá reemplazar los anillos en O.
Cerciórese de que no hayan fugas.
3.Debe mantener la entrada limpia y
sin obstrucciones. Igualmente la debe
revisar periodicamente. Voltee la
bomba y quítele el tornillo que se
encuentra debajo de la salida de ésta.
Gire la base en el mismo sentido de
las agujas del reloj para abrirla.
Saque la base y bote la basura que se
haya acumulado.
Acción a Tomar
1. Brevemente desenchufe la bomba para reinicializar
2. Si el fusible está quemado reemplácelo con un similar o active el
cortacircuito
3. Si el voltaje es más bajo que el recomendado, chequee el alambrado. En
caseo de que éste sea adecuado contacte la compañía de electricidad
4. Reempláce la bomba
5. Si el impulsor no gira, saque la base para botar el desperdicio
acumulado
6. Reponer la bomba en dos pulgadas (4 cm) por lo menos de agua para
cebarla en forma adecuada
1. Ninguna acción necesaria. Refiérase a Modos de Operación para la
explicación de los modos de operación
2. El agua no debe estar a más de 49˚C (120˚F)
3. Reemplácela o muevala a otro sitio
Precaucion:La bomba se puede encender sin previo aviso.
Desconecte el cordón de la línea de tensión antes de darle servicio
1. Reempláce la bomba
2. Quite la base, limpie el impulsor
3. Reemplace parte de la tubería con un conector flexible
1. Si el voltaje es más bajo que el recomendado, chequee el alambrado.
En caso de que éste sea adecuado contacte la compañía de electricidad
2. Saque, limpie y apriete bien el impulsor
3. Sustituya la bomba. Limpie las piezas que lo necesiten
4. Haga todos los calculos de nuevo para ver si está usando la bomba
adecuada
5. Saque y revise la válvula de chequeo para ver si está bien instalada y
funcionando correctamente
6. Compruebe la válvula de cebado automática. Esta debería moverse
libremente hacia dentro y fuera. Si el problema persiste, retire la
válvula de retención y conecte el conector de la manguera de jardín
directamente a la bomba.
7 Sp
WEU250

Advertisement

loading