Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could
result in personal injury and/or property damage! Retain instructions for future reference.
Description
The electronically controlled
submersible utility pump is designed to
automatically detect the presence of
water. If water is detected the pump will
run. If no water is detected the pump
will enter a "Sleep Mode". The unit is
equipped with an 15-ft., 3-prong
grounding-type power cord. The motor
is sealed and designed to operate under
water. The pump includes a removable
check valve, and a fitting to accept either
a 1 inch pipe or a 3/4 inch garden hose.
IMPORTANT: THIS PUMP IS NOT
SUITABLE FOR AQUATIC LIFE!
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates
a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2008 Wayne Water Systems
Submersible Automatic
Utility Pump
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
CALIFORNIA PROPOSITION 65
This product or its
power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
General Safety
Information
1. Know the pump application,
limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.
Do not
use to
pump flammable or explosive
fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in
flammable and/or explosive atmospheres.
Pump should only be used with liquids
compatible with pump component
materials. Failure to follow this warning
can result in personal injury and/or
property damage.
2. Make certain that the power source
(electric motor) conforms to the
requirements of the equipment.
Disconnect power before ser-
vicing. If the power discon-
nect is out of sight, lock in
the open position and tag it to prevent
unexpected application of power. Fail-
ure to do so could result in fatal elec-
trical shock!
3. Release all pressure within the system
before servicing any component.
4. Drain all liquids from the system before
servicing.
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
WEU250
5. Secure the discharge line before starting
the pump. An unsecured discharge line
will whip, possibly causing personal
injury and/or property damage.
6. Check hoses for weak and worn
condition before each use, making
certain that all connections are secure.
7. Periodically inspect the pump and
system components. Perform routine
maintenance as required (See Mainte-
nance Section).
This utility pump is
not constructed to
handle laundry discharge or any other
application which may contain caustic
chemicals and/or foreign materials. Pump
damage could occur if the pump is used
in these applications.
8. Provide a means of pressure relief
for pumps whose discharge line can
be shut-off or obstructed.
9. Personal Safety:
a.Wear safety glasses at all times
when working with pumps.
b.Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c.Keep visitors at a safe distance from
the work area.
10. When wiring an electrically driven
pump such as this, follow all
electrical and safety codes, as well
as the most recent National
Electrical Code (NEC) and the Occu-
pational Safety and Health Act
(OSHA).
11. This equipment is only for use on 120
volt (single-phase) and is equipped
with an approved 3-conductor cord
and 3-prong, grounding-type plug as
shown in Figure 1.
Grounded Outlet
Grounding
Blade
Figure 1
322405-001 9/08

Advertisement

Table of Contents
loading

Summary of Contents for Wayne WEU250

  • Page 1 Figure 1 REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2008 Wayne Water Systems For parts, product & service information 322405-001 9/08 visit www.waynepumps.com...
  • Page 2: General Safety Information

    Operating Instructions General Safety Installation Operation Information (Continued) IMPORTANT: This pump is not designed Do not touch for use in septic tanks or underground To reduce the risk of electric shock, pump, pump motor, water or vaults to handle raw sewage or effluents. the motor must be securely and discharge piping when the It should never be used in hazardous or...
  • Page 3: Maintenance

    WEU250 Operation If problem persists, remove check valve (continued) Garden Hose and connect garden hose connector Connector 3. The motor is equipped with an directly to pump. automatically resetting thermal If the outlet of the discharge hose / overload protector. If the motor gets...
  • Page 4: Limited Warranty

    Limited Warranty For two years from the date of purchase, Wayne will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship.
  • Page 5: Medidas De Seguridad

    Figura 1 que PODRIA ocasionarle heridas no muy graves. RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía! Adjúntela a este manual o archívela en lugar seguro. © 2008 Wayne Water Systems 322405-001 9/08 5 Sp...
  • Page 6: Instalación

    Manual de Instrucciones Informaciones NOTA: La bomba viene de fábrica con Funcionamiento una válvula de control de descarga y un Generales de Seguridad Nunca adaptador para manguera de jardín. La toque la válvula de control debe ser usada para (Continuación) bomba, el motor, agua o prevenir que el agua se devuelva por la Para reducir el peligro de...
  • Page 7: Mantenimiento

    WEU250 Funcionamiento Si el problema persiste, retire la Conector de válvula de retención y conecte el (Continuación) Manguera conector de la manguera de jardín de jardín Si el protector de sobrecarga para la directamente a la bomba. bomba repetidamente, desconecte la Válvula de...
  • Page 8: Garantía Limitada

    Garantía Limitada Durante dos años a partir de la fecha de compra, Wayne reparará o reemplazará para el comprador original, según lo que decida, cualquier pieza o piezas de su Bombas de resumideros o Bombas de agua ("Producto") que después de un examen Wayne encuentre que tenían defectos en su material o mano de obra.