At least once a year, have a qualified service technician clean, check and grease the unit.
Clean rails, racks and wheels. Regrease gear rack teeth ONLY.
Check for dry and /or worn belts. Lubricate or replace as needed.
Check for rail wear. There should be no groove.
Clean charging contacts (both carriage and rail ends) using Scotch Brite®.
Check battery voltage (load test).
Check safety switches (footrest, carriage, seat).
Check armrest switch and keyswitch (if applicable).
Check battery charger output:
Load test using remote controls. Check voltage while carriage
is traveling up.
Test with carriage against contacts.
Test with carriage away from contacts.
Check contacts and lights.
Check speed.
Check seat positioning belt for wear and proper operation.
Examine exposed wiring. Are there any cuts or abrasions?
Verify operation of seat swivel mechanism. Does it moves easily and lock in place
correctly?
Check that all hardware is properly tightened.