3.2.3
Connecting external sensors
Fig. 3: WC flush plate, terminal assign‐
ment for external sensors
Fig. 4: WC flush plate, terminal assign‐
ment for external sensors
WC flush plate for Prevista Visign for More 205 sensitive
NOTICE!
Damage to property due to excess voltage
If you apply voltage to the connection cable for the
external button, you will damage the control.
Do not apply any external voltage!
n
Requirements:
Button with locking function or potential-free contact (closure time at
n
least 350 ms) available
Connection cable available
n
▶
Connect the contact to actuate the small flush volume between the
green (1) and yellow cable (3).
▶
Connect the contact to actuate the large flush volume between the
green (1) and white cable (2).
▶
Strip the end of the brown cable (e.g., with a lustre terminal).
Handling
21