Compatible 5700 Series Transmitters - ADEMCO N7227V5 Installation Instructions Manual

Vista user guide security camera n7227v5
Hide thumbs Also See for N7227V5:
Table of Contents

Advertisement

Compatible 5700 Series Transmitters

Model
Product
5701
Panic Transmitter
5706
Photoelectric Smoke
Detector
5711
Slimline Door/
Window Transmitter
5715WH
Universal Transmitter
5716
Door/Window
5716WM
Transmitter
5742
Audio Discriminator
5743
Dual Technology
Glassbreak Detector
5775
PIR Detector
5727
Wireless Keypad
5827BD
Wireless Keypad
(usable in a 5700 System)
5799
Magnets
U L
The 5711, 5715, and 5716 do not supervise their loop wiring for shorts.
Therefore, for UL Household Burglary installations, the loop wiring may not
exceed 3 feet.
Zone/ID #
Description
62 or 63
• Programmable for either silent or
audible 24-hour alarm.
48–55
• One-piece smoke detector with
built-in transmitter.
• Built-in UL Listed 85dB piezo
electric alarm sounder and audible
low battery warning.
10–63
• Can be used with any closed or
open circuit sensor.
10–63
• DIP switch selectable for fast res-
ponse, and open or closed sensor
usage.
• Has a tamper protected cover.
10–63
• Can be used with any open or
closed circuit sensor.
• Features a built-in reed switch.
• 5716WM includes magnet.
10–63
• For use in unoccupied areas to
detect the sound of shattering glass
when a window is broken.
10–63
• Detects the sound and shock of
breaking glass and requires the
presence of both to initiate an
alarm condition.
32–47
• Dual element passive infrared
detector with built-in selectable
pulse count.
Note : There is a 3-minute lock-out
between fault transmissions to con
serve battery life.
House ID
• Can be used to turn the burglary
protection on and off.
• Features the same built-in panic
functions as wired keypads.
• Identified as zone "00" (on wired
keypads) when it transmits with a
low battery.
House ID
• Requires use of 5800TM Module.
• RF House ID must be programmed
in field 24, and the wireless key-
pad set to the same ID.
• Operates the system similarly to
wired keypads
• Can indicate system status via its 3
LEDs and sounder.
• Includes 3 panic keys.
• Package of 8 magnets for use with
5716 transmitters
– 27 –