ADEMCO N7227V5 Installation Instructions Manual page 29

Vista user guide security camera n7227v5
Hide thumbs Also See for N7227V5:
Table of Contents

Advertisement

Data field 22 RF SYSTEM TYPE, must have been programmed for a 5700
RF system ("1"). Also, the House ID should have been entered in field 24,
and all 5700 transmitters set to the same House ID.
4. Press 56. (Zone Programming Mode)
Use this mode to program zone numbers, zone types, and alarm report
codes for all 5700 wireless zones that are going to be used in the system.
5700 transmitters are programmed into the system one at a time, starting
with the lowest Zone/ID number that has been assigned to it previously via
its DIP switches.
Example: If the first transmitter to be programmed has been set via its DIP
switches to Zone/ID 20, you will program zone types, and alarm report
codes for that transmitter in zone 20.
En te r Zn Nu m .
( 0 0 = Q u it)
2 0
Zone 20 entered
Zn ZT – RC I n : L
2 0 0 0 –
– : –
Zone Number
2 0 Zo n e T ype
P e r im e te r
0 3
Entry for Zone Type
03 shown
A detailed explanation of
each zone type is provided
in the ZONE RESPONSE
TYPE DEFINITIONS
section in the separate
Programming Guide.
2 0 Re po r t Co de
1 st 0 3 2 n d 1 2 3 C
2 0 I n pu t De vic e
RF T r a n s.
RF :
– 29 –
5. Enter the zone number that you wish to
program. As an example, zone 20 is shown
entered here.
Zone numbers between 10 and 63 can be
assigned to transmitters. However, the total
number of wireless zones that can be used is 8
for 5700 RF systems (see Table 1 on a
previous page).
6. A summary display will appear, showing the
status of that zone's program.
If it is programmed satisfactorily, press [#] to
back up one step and enter another zone
number, if desired.
If the zone is not programmed, or you want to
change it, press [ ]. A prompt for Zone Type
will appear.
7. Each zone must be assigned a zone type,
which defines the way in which the system
responds to faults in that zone.
Enter the zone type (or change it, if necessary).
Zone types that you can assign are listed below.
Enter the desired zone type code as listed.
00 = Zone Not Used
01 = Entry/Exit Burglary
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
When the display shows the zone type you
want, press [ ] to continue.
8. Enter the report code.
The report code consists of 2 hexadecimal
digits, each in turn consisting of 2 numerical
digits. For example, for a report code of "3C",
enter [0][3] for "3" and [1][2] for "C".
See the SYSTEM COMMUNICATIONS section
for complete information on report codes, if
necessary.
Press [ ] to continue.
9. For the hardwired zones (HW), and the zones
for a 5700 system's transmitters (RF), the Input
Device types are automatically assigned (Panic,
Duress, and Tamper inputs are not applicable).
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
23 = No Alarm
Response