Programming Panic Keys

00 = Zone Not Used
01 = Entry/Exit #1
02 = not used
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hr Silent
07 = 24 Hr Audible
You must enter "00" as the zone type for any hard-wired zones that are not
used.
02 Report Code
1st 03 2nd 12
3C
Typical summary display
Zn ZT – RC
In
02 03 – 3C
HW: –
Program Alpha?
0 = No 1 = Yes
0
Enter Zn Num.
(00 = Quit)
03
Enter next zone number
When programming zones, note the following:
The defaults for individual panic keys or panic key pairs are:
Zone 07.
& #, or B: zone type 06 (24-hr silent).
Zone 95. 1 & , or A: zone type 00 (not used).
Zone 96. 3 & #, or C: zone type 00 (not used).
Panic keys are programmed (or re-programmed) by keying the zone number,
e.g., 07, 95, and 96, and entering the desired zone type that will provide
the desired panic function for each of these keys, using the list of zone types
below.
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire
– 20 –
Zone Types
08 = 24 Hr Aux
09 = Fire
10 = Interior w/Delay
20 = Arm Stay*
21 = Arm-Away*
22 = Disarm*
23 = No Alarm
Response
* 5800 RF Systems only
When the display shows the zone type you
want, press [ ] to continue.
The report code consists of 2 hexadecimal
digits, each in turn consisting of 2 numerical
digits. For example, for a report code of "3C",
enter [0][3] for "3" and [1][2] for "C". Refer to the
SYSTEM COMMUNICATION section f o r
complete information on report codes, if
necessary.
Enter the desired report code and then press [ ]
to continue.
A summary display will appear, showing the
L
data for the zone that was just programmed.
If it is programmed satisfactorily, press [ ] to
continue.
The next request is to enter Alpha descriptors
for the zones. The entry may be done now
(enter 1), or may be done at a later time using
82 interactive mode (enter 0). See the ALPHA
DESCRIPTOR PROGRAMMING section for
specific procedure.
If "0" (no) was entered above, the system will
return to the Enter Zone Number prompt.
Proceed with the programming for the next
zone, i.e., [ ] and zone number.