4.3

Mounting a General-purpose Table (Fixed Type)

■ Confirming components
Confirm that all components have been delivered (see the table below).
General-purpose Table (Fixed Type)
Component name
Also, prepare the necessary tools:
・Phillips screwdrivers (No. 2 and No. 3 bits)
・Cage nut tool
The procedure for mounting a general-purpose table (fixed type) is as follows:
1. Insert cage nuts.
2. Attach rear brackets.
3. Mounting the table.
4.3.1
Inserting cage nuts
Insert cage nuts into the rack posts (front and rear). For more information on the mounting
procedure, see Section 4.1.1, "Insertion."
1
Open the front door, and insert the M6 cage nuts into the front post of the
rack.
Insert cage nuts into two upper and lower square holes out of three between the location lines.
The mounting locations are as follows: one nut in each of the upper and lower square holes
among the three square holes (height of 1U) at the location line marking the mounting
location of the table. Two nuts on each of the left and right sides make up a total of four nuts.
Table
Rear bracket L
Rear bracket R
M6 cage nut
M6 bolt
M6 screw
Belt
Installation Guide
Type name: 19R-16TR1
Quantity
1
1
1
8
4
8
2
1