Promise Technology
Specifications
Vess R3600 Series models
Form factor
Drives supported
IO Ports
per controller
Memory
Storage
Expansion
Operational
RAID support
RAID stripe size
Hot Spare
Drives
Power Supplies
Voltage
Current
(Maximum)
Power Conversion
Efficiency
Dimensions
(Height, Width, Depth)
Weight
(killograms)
(w/o drives)
(w drives)
3U 19" rack mount
•
Up to 16 3.5" drives
•
6/12 Gb SAS, 6 Gb SATA HDD and SSD
•
Supports any mix of SAS and SATA drives simultaneously in the same
enclosure
•
Four 1G IO plus One 1G Management / IO
•
One 12G SFF-8644 mini-SAS connector per controller for JBOD
expansion.
8GB x 1 per ctrl (up to 64GB)
Cascade up to twelve Vess J3600 JBOD expansion units.
Vess J3600 Series supports 16 drives per device.
0, 1, 5, 6, 10, 50, 60
64K, 128K, 256K, 512K, 1MB
Global, Dedicated and Revertible option
CRPS 550W; Efficiency 80PLUS Certified Redundant Power Supply
AC: 100-240VAC; DC: 180-320VDC Auto-Ranging
< 8A@100-240VAC@full load; < 8A@180-320VDC@full load
>80% @ 110V (>20% load), >80% @ 240V (>20% load)
131mm x 446.7mm x 507mm (5.2" x 17.6" x 19.96")
R3600tiD
19.8
31.0
R3600xiD
R3600iD
19.8
19.7
31.0
30.9
3
Introduction
R3604fiD
19.9
31.1