Stardance Direct Vent/Natural Vent Gas Heater
Parallel Installation: Minimum Clearance
and Flue Centerline, Direct Vent and
Natural Vent
C
D
C L
B
Stove Clearances:
Pipe Centerlines:
ST128b
Stardance
Fig. 3 Parallel installation, minimum back and side clear-
ances, and flue centerlines.
flue centerline
9/28/00 djt
Corner Installation:
Minimum Clearance and Flue Centerline,
Direct Vent and Natural Vent
B
B
A
Stove Clearance:
Pipe Centerline:
Fig. 4 Corner installation, minimum corner clearance and flue
centerline.
6
C L
A: 4" (102 mm)
B: 4" (102 mm)
C: 15¹⁄₂" (395 mm)
D: 9" (229 mm)
A
ST129b
A: 4" (102 mm)
B: 14¹⁄₂" (370 mm)
ST129b
Stardance
corner specs
9/28/00 djt
Direct Vent Only
A
ST128b
Effective Minimum
Wall Thimble
Centerline
Fig. 5 Minimum wall thimble centerline.

Wall and Ceiling Clearances

A: Rear Wall
B: Min. Clearance
C: Min. Alcove Height
ST101b
D: Max. Alcove Depth
Stardance
Sidewall Clearance
Direct Vent
Fig. 5 Dimensions and clearances to ceiling or alcove.
Min. Clrnc
9/28/00 djt
The Stardance Heater must be installed on rigid floor-
ing. When the heater is installed directly on any com-
bustible surface other than wood flooring, a metal or
wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other

hearth requirements.

Wall Centerline from Floor
A
56" (1480 mm) (CFM Pipe)
ST131b
52" (1378 mm) (Simpson Duravent Pipe)
Stardance
wall thimble
9/28/00 djt
D
B
C
4" (102 mm)
45¹⁄₄" (1154 mm)*
72" (1830 mm)
48" (1220 mm)
4" (102 mm)
Hearth Requirements
ST131b
A
ST101b
20007065