Vermont Castings SDDVTEB Homeowner's Installation And Operating Manual

Sddvt/sddvtc series direct vent/natural vent gas heater
Table of Contents

Advertisement

Quick Links

INSTALLER / CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer, service
agency or the gas suppler.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier from
your neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
This appliance may be installed in an after
market permanently located manufactured
(mobile) home where not prohibited by
local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
Stardance
Direct Vent/Natural Vent
Gas Heater
Models:
SDDVT Series: SDDVTCB, SDDVTEB, SDDVTBS,
SDDVTBD, SDDVTBM
SDDVTC Series: SDDVTCSCB, SDDVTCSEB,
SDDVTCSBS, SDDVTCSBD, SDDVTCSBM
Homeowner's Installation
and Operating Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
®
12734
Stardance Dv
cover
8/07
C E RT I F I E D
30004968 5/11 Rev. 6

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings SDDVTEB

  • Page 1 • If you cannot reach your gas supplier, call the fire department. DO NOT STORE OR USE GASOLINE OR OTHER Models: FLAMMABLE VAPORS AND SDDVT Series: SDDVTCB, SDDVTEB, SDDVTBS, LIQUIDS IN THE VICINITY OF THIS SDDVTBD, SDDVTBM OR ANY OTHER APPLIANCE. 12734 SDDVTC Series: SDDVTCSCB, SDDVTCSEB,...
  • Page 2: Table Of Contents

    Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: General Information

    General Information The Stardance Direct Vent/Natural Vent Room Heater, Model The Stardance Direct Vent/Natural Vent Room Heater, when in- Nos. SDDVTCB, SDDVTEB, SDDVTBS, SDDVTBD, SDDVTBM, stalled, must be electrically grounded in accordance with local SDDVTCSCB, SDDVTCSEB, SDDVTCSBS, SDDVTCSBD, SD- codes or, in the absence of local codes, with the National Electri-...
  • Page 4: Operating Installation Requirements For The Commonwealth Of Massachusetts

    Stardance® Direct Vent/Natural Vent Gas Heater Installation Requirements Requirements for the Commonwealth of Inspection Massachusetts The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not All gas fitting and installation of this heater shall only be approve the installation unless, upon inspection, the done by a licensed gas fitter or licensed plumber.
  • Page 5: Instructions Stove Dimensions

    Natural Vent unit in the field. If a Natural Vent heater is desired, the Vermont Castings Z31B00 FSDHAG Draft Hood must be directly installed to the top of the unit according to the installation instructions. The Draft Hood Adapter is available in the 7FSDHASK stove kit or as a separate item.
  • Page 6: Installation Requirements

    Stardance® Direct Vent/Natural Vent Gas Heater Installation Requirements The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z3.1/NFPA 54 - latest edition. (EXCEP- TION: Do not derate this appliance for altitude. Main- tain the manifold pressure at 3.5 inches w.c.
  • Page 7: Parallel & Corner Installation

    Stardance® Direct Vent/Natural Vent Gas Heater Parallel Installation: Minimum Clearance Wall Centerline from Floor and Flue Centerline, Direct Vent and Direct Vent Only Natural Vent ST131b ST18b Effective Minimum Stove Clearances: A: 4” (10 mm) Wall Thimble 56” (1480 mm) (MHSC Pipe) B: 4”...
  • Page 8: Gas Specifications

    90° Elbows ANSI Z21.88-2009 / CSA 2.33-2009 Vented Gas Fireplace Heaters The installation of your Vermont Castings stove must conform with local codes, or in the absence of local ST134a codes, with the National Fuel Gas Code ANSI Z3.1/ FDV28 NFPA 54 - latest edition, or CSA B149.1 Installation...
  • Page 9: Vertical Termination - Direct Vent Only

    Stardance® Direct Vent/Natural Vent Gas Heater Restrictor Plate Adjustment Vertical Termination - Direct Vent ONLY for Extended Pipe Runs A vertical vent system must terminate no less than 8’ (.44 m) and no more than 40’ (1 m) above the ap- The Stardance stove is shipped with a restrictor plate pliance flue collar.
  • Page 10: Vent Termination Clearances

    Stardance® Direct Vent/Natural Vent Gas Heater Vent Termination Clearances When planning the installation, consider the location Your stove is approved to be vented either through the of the vent terminal and clearances. Some of the most side wall, or vertical through the roof. common clearances to keep in mind are shown in •...
  • Page 11: General Venting Information - Termination Location

    Stardance® Direct Vent/Natural Vent Gas Heater General Venting Information - Termination Location INSIDE  CORNER DETAIL  G  V  N  H  A  D  E  L  C  B  B  V  Fixed B  V  Closed V  Fixed Operable Closed F  V  B  M  V  B  J ...
  • Page 12: Termination Clearances

    Stardance® Direct Vent/Natural Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with no side wall with perpendicular side wall...
  • Page 13: Venting Requirements And Options - Direct Vent Only

    6” Straight, Blk. 4DT-06B These parts are available from DuraVent Corporation, 9” Straight, Blk. 4DT-09B Selkirk Corporation or your Vermont Castings Dealer. 4” - 10” Adjustable Straight Section Blk. 4DT-AJ1B See Figure 4 for dimensions relevant to the standard 1” Straight, Blk.
  • Page 14 Stardance® Direct Vent/Natural Vent Gas Heater MHSC Vent Components Twist Lock 12” Straight Pipe (CG) 7TFSDVP12 The following kits are available to meet the needs of (1) 1” Non-adjustable Pipe Twist Lock 12”-18” Straight Pipe (CG) 7TFSDVP1218 most installations. All pipe has a 7” outer diameter and (1) 1”...
  • Page 15: Assembly

    Stardance® Direct Vent/Natural Vent Gas Heater • Insert the rheostat through the hole in the back Install the Optional Fan - SDDVT Series of the left side of the valve bracket, aligning the If you are installing the optional convection Fan Kit locator pin with the smaller hole in that bracket.
  • Page 16: Venting System Assembly - Direct Vent

    Stardance® Direct Vent/Natural Vent Gas Heater Venting System Assemlby - Direct Vent General Information The Stardance is approved for installation only with the vent components listed on Pages 13 & 14. Follow the vent component instructions exactly. For U.S. installations: The venting system must con- form with local codes and/or the current National Fuel Gas Code, ANSI Z3.1/NFPA 54.
  • Page 17: Side Wall Termination Assembly

    Stardance® Direct Vent/Natural Vent Gas Heater Secure with a minimum of two #8 x 1/4” sheet metal screws and seal with hi-temp silicone. Inner Adapter 1/4-0 x Pipe 3/8 Phillips For units factory equipped with appliance adapters from Screws other brands of Direct Vent systems, it is permissible to simply slide a length of DT pipe over the appliance adapter.
  • Page 18 Stardance® Direct Vent/Natural Vent Gas Heater 1” (305 mm) Max. Length Sleeve #8 Sheet Metal Screws ST15 Fig. 26 Measure the horizontal length. sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Fig. 7) ST215 10.
  • Page 19: Vent Termination Below Grade

    Stardance® Direct Vent/Natural Vent Gas Heater Vent Termination Below Grade Recessed Wall Install Snorkel Kit #7FSDVSKS when it is not possible Firestop to meet the required vent termination clearances of 1” (305 mm) above grade level. The snorkel kit will allow Finishing Collar Sheet Metal installation depth of down to 7”...
  • Page 20: Selkirk Direct-Temp Metalbestos Direct Vent System

    Stardance® Direct Vent/Natural Vent Gas Heater Selkirk Direct-Temp Metalbestos Direct #7DVAIS Vent System Attic Insulation Shield Installation Instructions 1. Determine whether the length of pipe fits the appli- ance outlet by attempting to engage the parts. If the parts engage smoothly, proceed to Step . If ob- structions, interference or loose fit is noted, contact #7DVFS the appliance manufacturer or Selkirk Metalbestos...
  • Page 21: Horizontal Venting

    Stardance® Direct Vent/Natural Vent Gas Heater Gasket Outlet End Inlet End Lock Tab To Termination To Appliance ST9 Fig. 33 Joint connection. Horizontal Termination (HC) Trim Plate (TP) (Required if Wall Vent Termination (VC) Thimble is not used) Pipe Length Wall Thimble (WT) Storm Collar (SC) (Optional)
  • Page 22: Horizontal Installation

    Stardance® Direct Vent/Natural Vent Gas Heater Supporting DIRECT-TEMP: Vertical Support Offsets: Vertical installations can be supported by two methods: If any offsets are necessary in the vertical system, an Offset Support (OS) should be installed directly above Ceiling Support (CS) (used in flat ceiling installation) the upper elbow of the offset.
  • Page 23 Stardance® Direct Vent/Natural Vent Gas Heater NOTE: As a general rule, the wall thimble is optional in the U.S. However, there may be some manufacturers that require it. Contact the appliance manufacturer for information if uncertain. When installed in Canada, a Firestop (FS) wall thimble is required on all installations in which Placed on Top...
  • Page 24: Vertical Installation

    Stardance® Direct Vent/Natural Vent Gas Heater Horizontal Termination Vertical Termination Storm Collar Approved Silicone Sealant Here Flashing Offset Support Collar ST931 Fig. 41 Horizontal termination. Firestop Spacer Vinyl Siding Standoff Ceiling Horizontal Termination Support Ceiling Support Collar Plate ST93 Fig. 42 Vinyl siding standoff and horizontal termination. 7.
  • Page 25: Venting System Assembly - Natural Vent

    Direct Vent Heater. It may be converted to a Natural until assembly extends to a point above the roof which Vent heater by installing the Vermont Castings Model complies with local code requirements for minimum ter- Z31B00 FSDHAG Draft Hood Adapter.
  • Page 26: Install The Vent Pipe

    Stardance® Direct Vent/Natural Vent Gas Heater For U.S. installations: The venting system must con- form with local codes and/or the current National Fuel Gas Code, ANSI Z.1. MHSC Direct Vent Decorative System may be 7” Pipe For Canadian installations: The venting system must used after Draft Hood up to the conform to the current CSA B149.1 installation code.
  • Page 27 Stardance® Direct Vent/Natural Vent Gas Heater Pilot Assembly Figure 47 Raised Notch Raised Notch LG497 Figure 48 3. Install the left log by mating the hole on the bottom of the log with the pin in the ember Left Log bed.
  • Page 28: Connect Gas Supply Line

    Burner Information The appliance must only use the gas specified on the rating plate, unless converted using a Vermont Castings ON/OFF Switch or ST315 Fuel Conversion Kit. To convert from Natural Gas to LP...
  • Page 29: Thermostat Connection (Optional)

    Stardance® Direct Vent/Natural Vent Gas Heater Install the Front Plate Thermostat Connection (optional) Hold the front plate by the window bars and lift it into Use only a thermostat rated for 500 millivolts. position, engaging the two steel tabs on the top corners Check the table below for the appropriate gauge ther- behind the adjacent bosses in the side plates.
  • Page 30: Operation

    Stardance® Direct Vent/Natural Vent Gas Heater Operation Pilot and Burner Inspection Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figure 56. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for as- sistance.
  • Page 31: Lighting And Operating Instructions

    Stardance® Direct Vent/Natural Vent Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- Follow the gas supplier’s instructions.
  • Page 32 Stardance® Direct Vent/Natural Vent Gas Heater Troubleshooting the Gas Control System (SDDVT Series) SIT NOVA 820 MILLIVOLT VALVE NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. Symptom Possible Causes Corrective Action 1.
  • Page 33: Instructions For Rcsitea (Sddvtcs Series)

    Stardance® Direct Vent/Natural Vent Gas Heater Instructions for RCSITEA . The switches on the transmitter and receiver must match in order for the system to work. SDDVTCS Series 3. To check, press either the ON or OFF button on the CAUTION: The RCSITEA is only certified for use on transmitter and the receiver indicator light will blink.
  • Page 34 Stardance® Direct Vent/Natural Vent Gas Heater 4. There will be a slight delay in the response of the Initial Startup unit (on/off) to a temperature. Room temperature is Figure 60 monitored every three (3) minutes. 1. After initial power up or °F 5.
  • Page 35 Stardance® Direct Vent/Natural Vent Gas Heater Transmitter Thermal Shutdown . Use the ON / ▲ button to set the desired On Figure 68 Delay Time from 0 to 15 1. If transmitter measures minutes. a r o o m t e m p e r a t u r e 3.
  • Page 36: Troubleshooting For Rcsitea

    Stardance® Direct Vent/Natural Vent Gas Heater Testing Remote Control System 1. Light the gas appliance following the lighting instruc- tions on Page xx. Confirm the pilot light is on; it must be in operation for the remote control to operate the main gas valve and blower.
  • Page 37: Fuel Conversion Instructions

    Stardance® Direct Vent/Natural Vent Gas Heater Fuel Conversion Instructions nal key-way of WARNING! This conversion kit shall be installed the screw (Fig. by a qualified service agency in accordance with 71), rotate it the manufacturer’s instructions and all applicable Figure 70 counterclock- Figure codes and requirements of the authority having...
  • Page 38 Stardance® Direct Vent/Natural Vent Gas Heater . Replace pilot orifice. SDDVTCS Series Models 3. Remove pilot hood by lifting up. (Fig. 77) Do not 1. Using the TORX T0 bit remove and discard the remove snap ring to remove pilot hood. NOTE: It is three (3) pressure regulator mounting screws from not necessary to remove the pilot tube for conver- the old pressure regulator assembly.
  • Page 39 Stardance® Direct Vent/Natural Vent Gas Heater Orifice Orifice Venturi Bracket Bracket Orifice Air Shutter Bracket CO14 Fig. 82 The air shutter setting is 1/” (13 mm) from the orifice Pem Studs bracket to the edge of the air shutter. ST919 All Models Fig.
  • Page 40: Maintenance

    Stardance® Direct Vent/Natural Vent Gas Heater Maintenance Your Stardance Gas Heater will provide years of service Cleaning the Glass with minimal upkeep. The following procedures will help WARNING: Allow the glass to cool com- ensure that your stove continues to function properly. pletely before attempting to clean.
  • Page 41: Gasket Replacement

    Do not use your stove if the flame pattern differs from should be replaced. New gasket is available from your that shown here. Contact your Vermont Castings dealer dealer. or a qualified technician for help.
  • Page 42: Wiring Diagrams

    Stardance® Direct Vent/Natural Vent Gas Heater Wiring Diagrams - SDDVT On/Off Switch POWER CORD Wiring TP/TH Millivolt Gas Valve Black Chassis ST14b Ground Thermostat Thermostat Optional Thermostat (Optional) (Optional) Wiring St124b FAN JUNCTION BOX on/off/switch TP/TH wiring Millivolt 1/11/00 djt Gas Valve Strain Relief Black...
  • Page 43 Stardance® Direct Vent/Natural Vent Gas Heater Wiring Diagrams - SDDVTCS Black 120V AC Adapter Black T  H mV Valve Receiver T  P   /   T   H   120V AC Plug Female Male SIT HI / LO 120V AC Valve Blower ST1091a Fig. 90 SIT Hi/Lo blower schematic. ST1090 120V AC Plug for Receiver SIT valve wiring...
  • Page 44: Replacement Parts

    MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Stardance Direct Vent/Natural Vent Gas Heater 4968 Stardance Models: SDDVT/TCS parts 8/09 SDDVT Series: SDDVTCB, SDDVTEB, SDDVTBS, SDDVTBD, SDDVTBM SDDVTCS Series: SDDVTCSCB, SDDVTCSEB, SDDVTCSBS, SDDVTCSBD, SDDVTCSBM 30004968...
  • Page 45 Stardance® Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater SDDVT Series: SDDVTCB, SDDVTEB, SDDVTBS, SDDVTBD, SDDVTBM SDDVTCS Series: SDDVTCSCB, SDDVTCSEB, SDDVTCSBS, SDDVTCSBD, SDDVTCSBM Ref. Description SDDVT/SDDVTCS Log Set - Complete 001551 Log Rear 001546 Log Right 001548...
  • Page 46 Stardance® Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater SDDVT Series: SDDVTCB, SDDVTEB, SDDVTBS, SDDVTBD, SDDVTBM SDDVTCS Series: SDDVTCSCB, SDDVTCSEB, SDDVTCSBS, SDDVTCSBD, SDDVTCSBM Ref. Description SDDVT/SDDVTCS Sensor 1450 CMG-8184-003 (for use with FSDHAG only) 1000013 Wiring Harness...
  • Page 47 Stardance® Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater SDDVT Series: SDDVTCB, SDDVTEB, SDDVTBS, SDDVTBD, SDDVTBM SDDVTCS Series: SDDVTCSCB, SDDVTCSEB, SDDVTCSBS, SDDVTCSBD, SDDVTCSBM Shell Enamel Part Numbers Color Left End Right End Front OP Left Door* Right Door* Left Door** Right Door**...
  • Page 48: Optional Accessories

    Stardance® Direct Vent/Natural Vent Gas Heater Optional Accessories Fan Kit - STDDVT Screen Kit FK26 Fan An optional screen, S30SK, for use with the operable doors is available to allow the doors to be left in the The FK6 fan helps distribute heated air from within open position.
  • Page 49 Stardance® Direct Vent/Natural Vent Gas Heater 30004968...
  • Page 50 Stardance® Direct Vent/Natural Vent Gas Heater 30004968...
  • Page 51: Warranty

    LIMITED LIFETIME WARRANTY Stardance® Direct Vent/Natural Vent Gas Heater PRODUCT COVERED BY THIS WARRANTY All Vermont Castings brand gas stoves, gas inserts, and gas fireplaces installed in the United States of America or Canada. LIMITED LIFETIME WARRANTY • Any part or component replaced under the provisions of this...