Vermont Castings Stardance SDV30 Installation And Operating Manual page 32

Direct vent/natural vent gas heater
Hide thumbs Also See for Stardance SDV30:
Table of Contents

Advertisement

Stardance Direct Vent/Natural Vent Gas Heater
Models 3940, 3950 (RF Models) Only
16. Follow procedure for pilot type 2 to replace pilot
orifice.
17. Remove and replace plug on lower right hand side
of the valve; Red for LP and Blue for NG. (Page 26,
Fig. 49)
18. Remove motor top cap. Depress and turn center
plunger until arrow points to correct screw. Red for
LP and Blue for NG. NOTE: Plunger will "snap" into
NG position when arrow is close to blue screw. It will
not "snap" at LP (Red) position. (Fig. 61)
19. Insure manifold pressure remains between 3.2"
- 3.5" w.c. for NG and 9,5" - 10" w.c. for LP. To adjust
the manifold pressure, for NG, using a torque #10
key turn the blue screw clockwise to increase the
manifold pressure. Turn the screw counterclockwise
to decrease the pressure. Use the red screw to
adjust LP.
20. Replace motor top cap.
Center
Plunger
Blue - NG
Red - LP
Fig. 61 Depress and turn center plunger.
Kit #
000-5021
000-5011
Kit #
000-5022
000-5012
32
Motor Top Cap
Valve
FP1037b
Table 2. Injector Orifice Size Matrix
FP1037b
comfort valve
Conversion to Natural Gas
convert
3/6/01 djt
Front
Part #
#54 / .055"
30000514
Conversion to LP
Front
Part #
#69 / .029"
30000513
All Models
21. Replace burner. Slide the burner in at an angle
with left side lower than the right side. Slide the left
side onto the injectors, making sure the burner leg
remains at a 90° angle to the base. Lower the right
hand side down in to place. Make sure the burner is
as far left as possible and the injector shoulders are
inside the burner.
NOTE: It is very critical to keep the left burner leg,
which holds the injectors, at a 90° angle to the base.
(Fig. 62) This keeps the orifices aligned with the
tubes inside burner. Failure to do so could affect the
flame appearance and performance of the unit.
22.Place conversion label on valve.
23.Reinstall the right and left log bracket assembly.
24.Reinstall the rear log bracket.
25.Replace logs.
26.Replace glass and stove front.
Conversion is complete.
OFF
Fig. 62 Remove and replace injector orifices.
Rear
Part #
#44 / .086"
30000334
Rear
Part #
#54 / .055"
30000514
Left Burner Leg
Injector Orifice
90°
Input (Btu/h)
Minimum
Maximum
19,000
28,000
ST353a
Input (Btu/h)
injector orifice
Minimum
Maximum
replace
20,000
28,000
3/21/00
djt
ST353a
20007065

Hide quick links: