Vermont Castings Stardance SDV30 Installation And Operating Manual page 31

Direct vent/natural vent gas heater
Hide thumbs Also See for Stardance SDV30:
Table of Contents

Advertisement

Fig. 55 Remove mounting screws, pressure regulator tower
and spring and diaphragm assembly.
E
F
Fig. 56 Replace regulator.
FC108
Pilot Orifice Conversion
SIT
1. Locate pilot. (Fig. 53)
regulator
2. Replace pilot orifice.
conversion
Pilot Type 1
10/03
• Remove pilot hood by lifting up. (Fig. 57) Do not
remove snap ring to remove pilot hood. NOTE: It is
not necessary to remove the pilot tube for conver-
sion.
• Remove pilot orifice with Allen wrench. (Fig. 58)
• Install the conversion orifice.
• Reinstall pilot hood. Be sure to align hood with
index tab.
20007065
A
B
C
FC107
SIT820
valve conversion
10/03
D
FC108
Stardance Direct Vent/Natural Vent Gas Heater
Pilot Hood
Pilot
Bracket
Fig. 57 Remove pilot hood.
Index Tab
FC107
Snap Ring
Fig. 58 Remove pilot orifice.
Pilot type 2
• Loosen pilot hood turning counterclockwise using a
7/16" wrench. (Fig. 59) NOTE: You may use pen-
etrating oil to prevent pilot hood threads from seizing
up.
• Remove pilot orifice with needlenose pliers. (Fig.
60) NOTE: Use a wrench to hold pilot tube in place
while removing the orifice.
• Install the conversion orifice.
• Reinstall pilot hood and tighten until mark on pilot
hood aligns with mark on pilot bracket.
NOTE: Be sure burner leg remains at a 90° angle to
firebox base after conversion.
Index
Marks
Pilot Bracket
Fig. 59 Remove pilot hood. (Your pilot may have a different
appearance.)
Fig. 60 Remove pilot orifice.
Allen Wrench
CO105a
gas conversion
Pilot
1/28/00 djt
CO106a
DV360/580
Gas Conversion
Pilot2
1/28/00 djt
Pilot
CO105
Gas Conversion
Pilot Orfice
Pilot
2/15/99 djt
CO106a
Gas Conversion
CO105a
CO106a
CO105
CO106b
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3900-39163940-3956

Table of Contents