Completion Status - Toshiba V Series Operation Manual

Integrated controller, control network fl-net opcn-2, module
Hide thumbs Also See for V Series:
Table of Contents

Advertisement

A.4 Completion Status
No
Completion name
1 Normal completion
2 Own node error
3 Own node standby
4 Timeout
5 Length error
6 Station mode error
7 Own node parameter not set
8 Transmit prohibit status
9 Format error
10 Transmit in progress
Own station IP address
11
error
12 LP to OS information error
Corresponding port user
13
busy
14 Corresponding port OS busy -5102 S controller is executing message transmission, FL312 dedicated request
15 Transmit timeout
16 Response timeout
17 M_RLT=Abnormal receive
M_RLT=Unsupported
18
receive
19 Undefined M_RLT receive
20 Receive data size error
Receive data area length
21
error 1
Receive data area length
22
error 2
6F8C1067
Table A-1 Completion status
Code
0
Request completed normally
-1
Request cannot be processed because own node entered down mode
Response when following request is issued in standby mode
(1) Common memory read request
-2
(2) Common memory write request
(3) Message transmit request
Write data was not transmitted for 2 seconds during cyclic data write
-31
re-quest
(1) Message transmit request "Transmit data length"
(2) Common memory read request "Read word count"
-47
(3) Common memory write request "Write word count"
is abnormal
(1) Parameter setup request was issued outside standby mode
-63
(2) Standby request was issued outside run mode
(3) Run request was issued outside standby mode
-79
Run request was issued without setting own node parameter
Cyclic transmission/message transmission is prohibited, but related
-95
re-quest was issued from S controller
(1) Format error in request text
-111
(2) Non-existing request type was used for RAS information read request
-113
Request code error/Non-existing request code used
-114
Set time request: Year error
-115
Set time request: Month error
-116
Set time request: Date error
Response in the following case for message transmit request
(1) Request cannot be processed because other node is transmitting
-166
(2) ACK was abnormal
(3) Re-transmit count exceeded
Non class C address was specified for FL312 IP address during parameter
-161
setup request
-5100 XMIT_T FB parameter error (data length specification)
Other XMIT_T FB is executing message transmission, FL312 dedicated
-5101
request
FL312 did not receive within 3 seconds after request was issued with
-5104
XMIT_T FB
With message transmission request, response was not received from
-5105
opposite node within 10 seconds after issuing request with XMIT_T FB
With message transmission request, abnormal response was received
-5106
from opposite node (M_RLT=1)
With message transmission request, unsupported response was received
-5109
from opposite node (M_RLT=2)
With message transmission request, undefined M_RLT was received from
-5112
opposite node
-5115 Receive data size is 1024 word or greater
If receive data < data area
-5116
Does not occur for RAS read, profile read, or log read request
If data area < receive area
-5117
Receive data is copied only for data area worth
A.4 Completion Status
Description
-117
Set time request: Time error
-118
Set time request: Minute error
-119
Set time request: Second error
A