A.4.8 Power
INPUT VOLTAGE
INPUT CURRENT
MAXIMUM POWER
ACC/IGNITION
DO
CONNECTOR
A.4.9 Dimensions and weight
TYPE
LENGTH x WIDTH x HEIGHT
WEIGHT
A.4.10 Environmental specifications
TEMPERATURE
HUMIDITY
Note
If the device is installed in a room where the ambient temperature exceeds 55 °C, the area must be re-
stricted and the device must have a "hot surface" warning label attached.
bintec H2 Automotive+
Input: 9-36 V DC
Nominal: 12-24 V DC
2 A@12Vdc
With a WWAN module installed: 12 W
With a WWAN+WIFI module installed: 15 W
With two WWAN+WIFI modules installed: 19 W
Input voltage: +12 - 24 V DC
Current: 7 mA@12Vdc, 14mA@24Vdc
Control Levels:
- ON: the same level as the INPUT VOLTAGE (+12 or +24 V DC)
- OFF: GND or not connected.
Digital output capable of sinking 250 mA.
4 Pin polarized connector
Ruggedized casing with multiple support positions.
237 x 180 x 59 mm
2.5 kg
Operating: -25°C to 70°C. (-22ºF to 185ºF)
Storage: -40°C to 80°C. (-13ºF to 176ºF)
Operating: 5% to 95% relative humidity (non-condensing)
Storage: 5% to 95% relative humidity (non-condensing)