2.6. Air Requirements

2.6. Air Requirements
If the -AC (air-cooling) option was purchased, use this option to cool the turning mirrors and dynamic
focusing module.
A gas supply pressure of 517 kPa to 586 kPa (75 psi to 85 psi) is required. Gas must be delivered via a
polyurethane air hose with an outer diameter of 4 mm. Unless otherwise specified, a gas flow rate of 20
SLPM (standard liters per minute) at 550 kPa (80 psi) should be observed.
If compressed air is used, it must be filtered to 0.25 microns, dry to 0º F dew point, and oil free.
l
If nitrogen is used, it must be 99.99% pure and filtered to 0.25 microns.
l
The filtration requirement is necessary to prevent particles from damaging the optical surfaces of the turning
mirrors.
W A R N I N G :  To prevent damage to the AGV3D, do not attach a water hose to an air fitting or
an air hose to a water fitting.
W A R N I N G : Wear eye protection when you are close to compressed air components.