Set Up Instruction - netvox R718H User Manual

Wireless pulse counter interface
Hide thumbs Also See for R718H:
Table of Contents

Advertisement

4.Set up Instruction

On/Off
Power on
Turn on
Turn off (Restore to factory setting) Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Power off
Note:
Network Joining
Never joined the network
Had joined the network
(Not at factory setting state)
Function Key
Press and hold for 5 seconds
Press once
Sleeping Mode
The device is on and in the
network
Low Voltage Warning
Low Voltage
Insert batteries. (users may need a flat blade screwdriver to open)
Press and hold the function key for 3 seconds till the green indicator flashes once.
Remove Batteries.
1. Remove and insert the battery; the device is at off state by default.
2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor
inductance and other energy storage components.
st
th
3. At 1
to 5
second after power on, the device is in engineering test mode.
Turn on the device to search the network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Turn on the device to search the previous network.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
The device is in the network: green indicator flashes once and sends a report
The device is not in the network: green indicator remains off
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report
according to Min Interval.
3.2V If the battery voltage is lower than 3.2V, the device will send a low-power warning
4

Advertisement

Table of Contents
loading

Table of Contents