Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
Wakes up and collects data
sleeping
sleeping
th
0H
15
M
Wakes up and
Wakes up and
collects data
collects data
REPORTS 3.6V
3.6V
Does not report
Notes :
1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not
collect data.
2) The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value,
the device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device
reports according to MaxTime interval.
3) We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up
frequently and the battery will be drained soon.
4) Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another
cycle of MinTime/MaxTime calculation is started.

6. Filtering time

100ms
130ms
40ms
10ms
*Pulse filtering time must be multiple of 5ms (can be set)
3.5V |3.5-3.6|=0.1
REPORTS 3.5V
...
th
th
30
M
45
M
Wakes up and
collects data
3.5V
Does not report
100ms
Users push the button,
REPORTS 3.5V.
Recalculate MaxTime.
th
th
1H
1H 10
M
1H 25
M
Wakes up and
Wakes up and
collects data
collects data
3.5V
3.5V
Does not report
Does not report
Ex1. The pulse = 100ms ; Accurately count
Ex2. The pulse > 100ms ; Accurately count
Ex3. 10ms < The pulse <100ms; Countable, but it could be missing.
Ex4. The pulse ≦10ms ; It will be filtered, not counted.
9
MaxTime
Wakes up and
collects data 3.5V
Does not report
th
th
1H 40
M
1H 55
M
Wakes up and
collects data
3.5V
Does not report
th
2H 10
M
Wakes up and
collects data
REPORTS 3.5V