Update Troubleshooting
Problem
PCBRPM 1:
During the update the
software application for the
RPM board is not correctly
transmitted. After restart of
the ergometer the error code
E:93 appears.
PCBRPM 2:
During the update the
software application for the
RPM board is not correctly
transmitted. After restart of
the ergometer the error code
E:93 appears.
- 60 -
D: Service Menu
Cause
The update of the RPM
software was interrupted.
The update of the RPM
software was interrupted.
eBike, eBike L, eBike EL
Remedy
The RPM board must be
dismounted. A jumper must be
plugged on the wrap connection
(see picture below) and the
RPM board must be mounted.
BILD
Restart the software update (see
step 6).
The start of the RPM board
download required a long time
(min. 25 s).
After finishing the download the
jumper must be unplugged.
Open the top cover (see section
B-2.1).
Set the miniature switch to the
"PROG ON" position (see picture
below).
Restart the software update (see
step 6).
The start of the RPM board
download required a long time
(min. 25 s).
Set the miniature switch to the
"PROG OFF" position (see
picture above) after finishing the
download.
2018112-003 Rev J