MAIN HUB TROUBLESHOOTING GUIDE
If Entire unit is not recognized by main hub, an entire row of prizes will show unavailable.
Step # 1 - Ensure individual Unit is communicating to Main Hub
Step # 2 - Refer to troubleshooting topics specific to a unit.
Step # 1
Verify 12 volt DC power to unit.
12 Volt power comes from Main Unit's power supply. There are jumper
cables that feed 12 volts to individual units.
(Cable part #'s: AACE1805, AACE1810, AACE1813, AACE1820)
Enter menu and got to "Diagnostic Menu"
Touch
Diagnostic
Menu
Verify dipswitches and flashing LED on unit's 1803 boards.
Yellow flashing is communication, red is an error in unit.
AACB1803
Spindle Unit
1 Flash from LED
All Dips OFF
Ensure phone cables are secure from silver socket on 1803 boards to correct socket on 1800 board.
AACB1800
Entire Hub Not Recognized
Touch Version
Information
Capsule Unit
2 Flashes from LED
Dips 3 & 4 ON
Locker
Hub
AAC-
Capsule
Hub
Spindle
Hub
Verify Unit is has version number in the #1 slot.
(#2 slot is for additional optional units)
Software version should start with:
1 for Spindle
2 for Capsule
3 for Locker
AACB1803
To Locker Unit
AACE1816
To Capsule Unit
AACE1811
To Spindle Unit
AACE1811
62
Main
Locker
Capsule
Hub
Hub
AACB1803
Locker Unit
3 Flashes from LED
Dip 4 ON
Spindle
Hub
Hub
Yellow light is
communication,
red is prize chute
sensor blocked,
or door locker
open, or other
error.