Furuno DSC-60 Service Manual page 68

Dsc/watch receiver
Hide thumbs Also See for DSC-60:
Table of Contents

Advertisement

3. REMOTE
By selecting RT, NBDP, DMC, or NMEA and pressing [ENT] key, Remote Test or Loopback Test is
executed. MIF command, CAID outputs for the tests.
These tests disregard RT PORT and NBDP settings in SYSTEM menu.
Remote test
Remote test
Remote test
Remote test
Remote test
The DSC-60 transmits test data to the connected equipment and receives the response #IDxxxx (where
xxxx is the model name. For example, when FS-1562 is connected, xxxx is FS1562). The command
outputs three times, and then, if no response occurs, "NG" is displayed.
If IC-302 is connected to the DMC terminal, DMC CHECK becomes "NG". In NMEA check, DSC-60
is connected to the NMEA terminal.
Results) Model name or NG
- RT
: FS-xxxx
- NBDP : DP-6
- DMC : DMC-5
- NMEA : DSC-60
Loopback test
Loopback test
Loopback test
Loopback test
Loopback test
This loopback test is executed to check internal I/O circuit for each port with the peripheral unit discon-
nected. Disconnect the unit connected to the port to be checked, and put a jumper between TX and RX
lines. #CAID command is sent out through the TX line and #ID is received through the RX line if the I/
O circuit is normal. The command outputs three times, and then, if no response occurs, "NG" is dis-
played.
Results) OK or NG
- RT
: OK
- NBDP : OK
- DMC : OK
- NMEA : OK
RT
NBDP
MAIN CPU
CONTROL/MODEM PCB
DMC
DSC-60
IEC
(NMEA)
DSC-60
MAIN CPU
CONTROL/MODEM PCB
Port
Connector terminal to short
#2 - #3
RT
#2 - #3
NBDP
#1 - #3 , #2 - #4
DMC
#1 - #3 , #2 - #4
IEC(NMEA)
5-7
3. Test through the Setup Menu
MIF COMMAND
#CAID
FS-xxxx
#IDFSXXXX
#CAID
DP-6
#IDDP6
#CAID
DMC-5
#IDDMC5
#CAID
DSC-60
#IDDSC60
RT
TX
NBDP
#CAID
DMC
RX
NMEA
IC-302