Sanitizing - Taylor C302 Operator's Manual

Slush freezer
Table of Contents

Advertisement

17. Place the large O-ring into the door groove and lightly
lubricate.
Figure 6-18
Note: Every 4 months or less, discard the O-rings
and install new O-rings.
18. Install the front bearing. Do not lubricate the front
bearing.
Figure 6-19
19. Install the freezer door. Position the door on the four
studs on the front of the freezing cylinder. Firmly
push the door into place. Install the four handscrews
on the studs and finger-tighten them equally in a
crisscross pattern to ensure that the door is secure.
Do not overtighten the handscrews.
Operating Procedures
11502
20. Repeat step 1 through step 19 for the other freezing
cylinders.

Sanitizing

Important! If a machine is sanitized and will not be
used for an extended period of time, clean water
should be used to flush all sanitizer from the lines.
11503
Remove the water from all the lines and components
prior to storage of the machine. Upon return to
service, the machine must be sanitized prior to use.
Note: The following instructions are for one side of
the machine. Each side consists of two freezing
cylinders, identified on the corresponding LCD as left
(L) and right (R).
1. Open the lighted display door. Place the control
switch in the ON position.
Model C302
OPERATING PROCEDURES
Figure 6-20
Figure 6-21
11504
6
13092
6-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents