Taylor C302 Operator's Manual page 22

Slush freezer
Table of Contents

Advertisement

USER INTERFACE
7. CO
PRESSURE LOW—When the CO
2
displays a lack of CO
start. If the CO
is not replenished at the end of the
2
60 seconds, both freezing cylinders will shut down
and this fault message will appear. Replenish the
CO
, and the fault message and warning tone will
2
clear.
FAULT DESCRIPTION
L: CO2 PRESSURE LOW
R: CO2 PRESSURE LOW
CLR
8. H
O PRESSURE LOW—When the water out
2
indicator displays a lack of water, a 60-second
internal timer will start. If the water is not replenished
at the end of the 60 seconds, all freezing cylinders
will shut down and this fault message will appear.
Replenish the water, and the fault message and
warning tone will clear.
FAULT DESCRIPTION
5
L: H2O PRESSURE LOW
R: H2O PRESSURE LOW
CLR
9. BRL NOT COOLING—A freezing cylinder check has
been established for the Auto mode of operation. If a
freezing cylinder enters the Auto mode, the control
will check product temperature. After 5 minutes, it will
again check product temperature. If product
temperature does not drop in that 5-minute time
span, the freezing cylinder will shut down and this
message will appear on the fault screen. For this
check to be valid, the product temperature must be
above 40°F (4.4°C).
FAULT DESCRIPTION
L: BARREL NOT COOLING
R: NO FAULT FOUND
CLR
5-4
out indicator
2
, a 60-second internal timer will
2
+ + +
SEL
+ + +
SEL
+ + +
SEL
10. BRL TEMP 2 HIGH—A maximum allowable product
temperature has been established to prevent product
from excessive heating. If the product exceeds
°
°
120
F (49
C) for any reason (in any mode of
operation), the entire machine shuts down.
FAULT DESCRIPTION
L: BARREL TEMP 2 HIGH
R: NO FAULT FOUND
CLR
Faults, when corrected, are cleared from the Fault
Description screen, with the following exception: BRL
NOT COOLING. This fault requires the operator to
press the OFF (<- -) key (when in the fault description
screen) in order for the fault to discontinue.
To see if there is more than one fault in either 
freezing cylinder, press the PRIME (+ + +) key. To
return to the operator menu, press the MENU
(SELECT) key once. To return to the main screen,
use the AUTO (- ->) key to cycle to menu item A, then
press the MENU (SELECT) key.
11. Screen C is SET CLOCK. Use the AUTO (- ->) and
OFF (<- -) keys to place the cursor under the element
to be set (hours, minutes, month, day, or year). Use
the PRIME (+++) and BEATER (- - -) keys to increase
or decrease the value. Press the MENU (SELECT)
key to advance to the Daylight Saving Time screen.
Note: The clock is programmed with military time.
SET CLOCK
14:30
<- - - -> + + +
This screen will appear if an invalid date is entered
(example: if the date entered exceeds the days of
that month).
SET CLOCK
14:30
Model C302
+ + +
2/25/04
- - -
SEL
02/31/04
INVALID DATE
User Interface
SEL
SEL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents