5 OPERATION
WARNING!
Secure the equipment, especially if used on an uneven or sloping surface.
5.1
Recommended maximum current values for connection
cables set
At an ambient temperature of +25 °C and a normal 10-minute cycle:
I
max
400 A (60% duty cycle)
350 A (100% duty cycle)
500 A (60% duty cycle)
400 A (100% duty cycle)
At an ambient temperature of +40 °C and a normal 10-minute cycle:
I
max
350 A (60% duty cycle)
300 A (100% duty cycle)
430 A (60% duty cycle)
375 A (100% duty cycle)
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading.
0463 691 001
Cable area
Cable length
0.5 ft (70
2-35 m
2
mm)
0.5 ft (95
2-35 m
2
mm)
Cable area
Cable length
0.5 ft (70
2-35 m
2
mm)
0.5 ft (95
2-35 m
2
mm)
- 18 -
Note
19 pole, 19 pole with coolant
19 pole, 19 pole with coolant
Note
19 pole, 19 pole with coolant
19 pole, 19 pole with coolant